MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
Cooling
Figure 12-3
MTS 4 Airflow
Cooling
Natural convection cooling is applied. For example there is no fan when MTS 2 operates with a load
of 295W for 2 BRs, low power PA, plus a charge current of 3 A @ + 30 °C.
Forced air from fans placed below units is used when for example MTS 4 operates with a
load of 640W for MTS 4 with 2 BRs, MTCC, high power PA plus a charge current of 6 A
@ + 30 °C. For all con
fi
gurations of MTS, see
6802800U74-N September 2009
12-5