MTS 2 and MTS 4 Installation, Con
fi
guration and Basic Service Manual
AC/DC Power Cabling
Table 5-2
AC/DC Power Cabling for MTS 4
Index
Cable Part
Number
From Unit/
Connection Name
To Unit/ Connection
Name
Notes
1a
Junction Panel/ DC1
Power Supply Unit 1/
DC In Battery
N/A
1b
3066551B01
Junction Panel/ DC2
Power Supply Unit 2/
DC In Battery
N/A
2
3066553B01
Junction Panel/ AC In 1
Power Supply Unit 1/
AC In
With retaining clip
3
3066553B01
Junction Panel/ AC In 2
Power Supply Unit 2/
AC In
With retaining clip
4a
Base Radio 1/ DC In
Pins: 1, 2, 3, 8, 10, and
11
4b
Base Radio 2/ DC In
Pins: 4, 5, 6, 9, 12, and
13
4c
Site Controller 1/ Power 1 Pins: 7 and 14
4d
3066545B01
Power Supply Unit 1/
DC Out
Site Controller 2/ Power 1 Pins: 7 and 14
5a
Base Radio 3/ DC In
Pins: 1, 2, 3, 8, 10, and
11
5b
Base Radio 4/ DC In
Pins: 4, 5, 6, 9, 12, and
13
5c
Site Controller 2/ Power 2 Pins: 7, 14
5d
3066545B01
Power Supply Unit 2/
DC Out
Site Controller 1/ Power 2 Pins: 7, 14
6
3066556B02
Junction Panel/
Bat Temp. 1
Power Supply Unit 1/
Battery Temp. Sens.
N/A
7
3066556B02
Junction Panel/
Bat Temp. 2
Power Supply Unit 2/
Battery Temp. Sens.
N/A
8
3066557B01
Power Supply Unit 1/
ATCC DC Out
ATCC 1/ DC In
Only for con
fi
guration
with ATCC
9
3066557B01
Power Supply Unit 2/
ATCC DC Out
ATCC 2/ DC In
Only for con
fi
guration
with two ATCCs
10
306659B01
ATCC 1/Inside ATCC
Interconnection
ATCC 2/Inside ATCC
Interconnection
Only for con
fi
guration
with two ATCCs
6802800U74-N September 2009
5-3
Summary of Contents for DIMETRA MTS 2
Page 4: ...This page intentionally left blank ...
Page 28: ...List of Procedures This page intentionally left blank xxii 6802800U74 N September 2009 ...
Page 30: ...List of Processes This page intentionally left blank xxiv 6802800U74 N September 2009 ...
Page 486: ...This page intentionally left blank A 10 6802800U74 N September 2009 ...
Page 492: ...This page intentionally left blank B 6 6802800U74 N September 2009 ...
Page 496: ...This page intentionally left blank C 4 6802800U74 N September 2009 ...