5-18
Gold Series™ Elite Inbound Event Display
2 Sort by Received Time Order then Primary/non-Primary
If the “Oldest on Top” (First-in-First-Displayed) was selected as shown
in the Received Time Order above,, then the selection is made to sort
first by Primary Resource (where RSC_A and RSC_B are Primary and
where RSC_C and RSC_D are non-primary), and second by Event
Status (e.g. Acknowledged, Unacknowledged, Held).
Thus, the Inbound Event Display would display events as shown in the
table below (no alphabetical sorting is implied). The first two events
are from Primary resources, and both are acknowledged.
Since oldest on top is specified, Event 1 (RSC_B) is displayed before
Event 2 (RSC_A). In each of the groups following those two
(separated for clarity here), the same criterion is applied.
Inbound Event State
UNIT_ID
Resource
Timestamp
Acknowledged 00000002
RSC_B
12:04
Acknowledged 00000008
RSC_A
12:22
Unacknowledged
00000006
RSC_A
12:11
Held 00000005
RSC_A
12:09
Acknowledged
00000001
RSC_C
12:05
Unacknowledged 00000007
RSC_D
12:08
Held 00000004
RSC_C
12:14
6880801D90-D