Issue 1.1 April 2006
Page 27
J905
J907
J906
J908
ODU
Connection
J905
J907
J906
J908
Remove links J906 and J907
Yellow Ethernet LED
Green Power LED
Recovery Switch
Figure 10: 150/300 PIDU - Remote LED and Recovery Switch Wiring
3.2.5 Cables and Connectors
The cable used to connect the 150/300 PIDU to the ODU can be any standard CAT5e type
provided that it is suitable for outdoor deployment. Motorola recommends that cables to the
specification below be used:
NEC/CEC: CMR (ETL) C (ETL) 75C SUN RES OIL RES II
Failure to use the recommended (or equivalent) standard of cable may invalidate the
system’s safety certification.
The cable used to connect the 150/300 PIDU to the users Network Equipment can be any
standard CAT5e Cable.
The 150/300 PIDU to ODU and 150/300 PIDU to Network Equipment cables may be
unscreened (UTP) or screened (STP). However, unscreened cables reduce the system’s
ability to cope with nearby lightning strikes. If lightning activity is common in the area of
deployment, the use of screened cable is highly recommended. See Section 12 “Lightning
Protection”.
The 150/300 PIDU provides screen continuity between the ODU and Network Equipment
connections.
The ODU network connection implements automatic MDI/MDI-X sensing and pair swapping
allowing connection to another piece of networking equipment or directly to end user
equipment.
3.2.6 Surge Arrestor
The 150/300 PIDU does not provide lightning or surge suppression. Should lightning or surge
suppression be required a separate Ethernet surge suppressor should be used and
appropriately grounded. Suitable surge suppressors can be sourced from your Motorola
distributor or reseller. See Section 12 “
L
ightning”.
Summary of Contents for Canopy 150 Mbps Backhaul
Page 1: ...Canopy 150 300 Mbps Backhaul User Guide BH150 300 UG en Issue 1 1 April 2006 ...
Page 25: ...Issue 1 1 April 2006 Page 24 Figure 5 Canopy 150 300 PIDU Power Input ...
Page 97: ...Issue 1 1 April 2006 Page 96 Figure 59 Spectrum Management Help Page ...
Page 162: ...Issue 1 1 April 2006 Page 161 Figure A8 Surge Arrestor ALPU ORT Connection Illustration ...