OPERATION / PROGRAMMING MANUAL
EN
MR14
The MR14 receiver is a wireless receiver for managing multiple MX14 emitters.
When receiving information from the emitter, it communicates with the automation
control board via cable, so that the automation can be stopped or reversed.
TECHNICAL CHARACTERISTICS
• Power Supply
12-32Vdc / 12-24Vac
• ECO Inputs
12/24V
• Relay
30Vdc 1A/125Vac 0.5A
• Working frequency
868MHz
• Memory for emitters
8
• Reach in the open
100m
• Dimension
81 x 65 x 20 (mm)
• IP
IP30
AES encryption
1
3
Basic operation:
Dipper 1 → ON;
Dipper 2 → OFF;
Dipper 3 → ON.
ECO
NORMAL
ACTIVED
BUZZER
DEACTIVATED
BUZZER
1
•
2
•
3
•
NC
COM
NO
Relay output NO channel 1
>
the output is active when any channel 1 emitter is in error
(ex: Door hit an obstacle, communication failed or the battery ran out).
The NC or NO output must be connected to the control board.
4
•
5
•
6
•
NC
COM
NO
Relay output NO channel 2
>
the output is active when any channel 2 emitter is in error
(ex: Door hit an obstacle, communication failed or the battery ran out). The NO
or NC output must be connected to the control board.
7
•
8
•
9
•
10 •
CH1
COM
CH2
COM
12/24V mode input
>
used to activate channel 1 or 2 in ECO mode (Dipper 1 OFF). The control
board must activate this input when the door starts to move.
11
•
12
•
+
-
12 / 24Vdc/ac power supply
LEDs
LED1, LED2, LED3 e LED4
- memory position indicators to be programmed for
channel 1
LED5, LED6, LED7 e LED8
- memory position indicators to be programmed for
channel 2
1 2 3
ON
NC COM NO
NC COM NO CH1 COM CH2 COM +
-
LED1 LED2 LED3 LED4 LED5 LED6 LED7 LED8
JOIN
SEL
1 2 3 4 5 6 7 8 9 10 11 12
INPUTS / OUTPUTS AND LEDS
DIPPER
1 • Transmission mode
• OFF – ECO mode
>
With ECO mode, devices will only communicate with each other when the automation is in
operation (opening or closing), in order to save energy.
To use this mode, it is necessary to connect the control board to the MR14 CH1 and / or CH2
inputs. When the door is stopped, communication takes place approximately every 30 seconds.
With the door moving, it will be done in intervals of 300 to 600 milliseconds.
•
ON
– NORMAL mode
> In this mode, communication is always done at intervals of 300 to 600 milliseconds, ignoring
energy savings.
As such, it is not necessary to connect the control board to the MR14 CH1 and / or CH2 inputs.
2 • Operation of CH1 and CH2 inputs (ECO mode)
>
Select the desired status for the CH1 and CH2 inputs information, paying attention to the
settings of the operator control board.
• OFF
– NO (MR14 and MX14 only communicate when the circuit is closed);
•
ON
– NC (MR14 and MX14 only communicate when the circuit is opened).
3 • Activate buzzer (audible alarm)
• OFF
– Buzzer Actived;
•
ON
– Buzzer deactivated.
2
NO
NC