INSTRUCTIONS

   

 

 

 

 

                                                                                

MODEL MHT-7000 

HIGH TECH 

AIR PREPARATION SYSTEM

 

580 CARNEGIE STREET                                                                                                            1-800-227-2822 
MANTECA, CA 95337                                                                                                          FAX 209-239-5114    
 

www.motorguard.com 

 

 

 

 

Rev 10/19

   

33170

 

 

 
 
 

  
 
The MHT-7000 High Tech Air Preparation System is an advanced air for spray booths and critical refinishing operations.  The system offers Six Stages 
of air preparation in a single unit and provides for the quickest, cleanest cartridge change in the industry. 
 

FEATURES

 

 

MHT-7100  

High-volume water trap combined with a hydrophilic depth cartridge 

that removes particulates, oil and water aerosols.  Overnight drain valve drains 
accumulated moisture when pressure is off. Uses (1) 

M-710 

drop-in replacement 

cartridge. 
 

MHT-7200  

Combines an activated carbon inner element to remove oil vapor to 

>.003 ppm with a high-capacity silica gel desiccant dryer that delivers -40°F dew 
point air.  Color change indicator changes from blue to pink, signaling the need to 
replace cartridge.  Uses (1) 

M-720

 drop-in replacement cartridge. 

 

MHT-7300  

High-capacity, true diaphragm regulator designed to set and hold 

pressure over a wide range of flows and conditions.  High-visibility, multi-scale 
pressure gauge features a scratch and solvent resistant glass lens.  Large, 
ergonomic adjustment knob locks to hold pressure setting. 

 

 

 

 

SPECIFICATIONS

 

 
Nominal Airflow Rating:       

      30 SCFM 

Maximum Inlet Pressure:  

      125 PSIG 

 

Outlet Pressure Range: 

       2-125 PSI 

Operating Temperature Range:     40-120 °F 

 
Install unit in spray booth or near critical operation with at least 20 feet of supply line between unit and compressor.  Failure to maintain this distance will 
cause excessive water vapor to pass through unit.  Unit is designed for installation in a 1/2" line; use appropriate fittings for installation in other line sizes.  
Apply pipe thread compound to male thread connections.  Before installing unit, relieve upstream pressure completely.  Install unit level and in direction 
of airflow as noted.  Unit should be mounted to a rigid structure and should not be supported by the supply line.   
 

WARNING:  This product is intended for use in industrial compressed air systems only.  Do not install where pressures or temperatures can 
exceed those listed above. 
 

Unit is supplied ready for use.  Air tight plugs should be removed just prior to installation to ensure desiccant and activated carbon are not exposed to 
air.  Supply valve (1) should be closed when unit is not in use. 
 
A 1/4” ID flexible drain hose may be connected to overnight drain valve (3) and routed to an approved drain to prevent water accumulation in work area.  

 

Before pressurizing, be sure bowls are turned fully clockwise.  Pressurize slowly to avoid high-pressure surge.  
 

 
Open service valve (2) fully so that handle is parallel to inlet pipe.  Turn knob on regulator clockwise to increase air pressure, counter-clockwise to 
decrease.  To reduce pressure setting, first reduce pressure to a setting lower than desired, then increase to the desired setting.  Push knob up firmly to 
lock and prevent accidental adjustment. 
 
Inspect daily for leaks. 
 
Check drain by shutting off supply pressure and relieving downstream pressure.  Accumulated liquid should drip slowly from drain. 
 