background image

IMPORTANT:

INSTRUCTION

MANUAL

Questions, problems, missing parts or for technical service? Before

returning to your retailer, call our customer service department at

1-888-942-6686.

model no. 009-5206-4

GEAR DRIVE

DIGITIAL TIRE INFLATOR 

Summary of Contents for 009-5206-4

Page 1: ...RUCTION MANUAL Questions problems missing parts or for technical service Before returning to your retailer call our customer service department at 1 888 942 6686 model no 009 5206 4 GEAR DRIVE DIGITIAL TIRE INFLATOR ...

Page 2: ...es Basketballs Sporting Equipment Small Beach Pool Inflatables INFLATOR APPLICATIONS FEATURES 1 This inflator is intended for use on high pressure applications including 1 5 5 6 6 7 7 8 8 9 9 10 11 13 12 4 2 3 APPLICATIONS ...

Page 3: ...e inflator Please carefully read the manual included with this product Misuse of the unit could cause property equipment damage and or personal injury Decrease pre set PSI level button Red hazard warning light button Valve stem cap Presta valve adaptor Work light button Display panel Fold down handle 120 V plug home Work light hazard light Increase pre set PSI level button Inflation nozzle Inflation ...

Page 4: ...ssure is reached OPERATION Begin by plugging in the inflator to the desired power source and selecting the appropriate source using the AC OFF DC selector on the top panel The current pre set pressure setting is shown on the left side of the LCD screen below the set gauge icon Setting a pre set pressure The pre set pressure setting can be adjusted by pressing the Increase or Decrease pre set PSI le...

Page 5: ...flator to cool for 15 minutes after 10 minutes of continuous operation Adjust to your desired pressure refer to Programmable pre set digital control Open the valve chuck by extending the lever and then push down the open end of the chuck onto the tire s valve stem Close the lever on the valve chuck to secure the connection Press the Start Stop button on the control panel and the inflator will begin...

Page 6: ...lever Then firmly insert the adaptor into the open end of the chuck Close the lever on the valve chuck to secure the adaptor Insert the adaptor onto the valve of object to be inflated Press the Start Stop button on the control panel and the inflator will begin to inflate When the object s pressure reaches the pre set pressure the inflator will stop automatically Also the inflator can be stopped manually...

Page 7: ...efore use WARNING Allow air compressor to cool for 15 minutes after 10 minutes of continuous operation Maximum Duty Cycle 40 at 35 PSI Do not touch the metal valve chuck adaptors or 12 V plug during or immediately after use as they may be hot Allow the unit to cool to room temperature before handling RISK OF EXPLOSION Do not overinflate objects Overinflation could cause damage and or personal injury...

Page 8: ... Voltage 12 V DC or 120 V AC Max Pressure 120 PSI Fuse 15 A Duty Cycle 10 minutes on 15 minutes off Accessories High Pressure Adaptors 3 pcs Spare Valve Stem Cap 15 A Spare Fuse TECHNICAL SPECIFICATIONS ENVIRONMENTAL PROTECTION SERVICING OF A DOUBLE INSULATED PRODUCT Double Insulation In a double insulated product two systems of insulation are provided instead of grounding No grounding means is pr...

Page 9: ...problèmes des pièces manquantes ou besoin de service technique Avant de retourner chez votre détaillant veuillez appeler notre service d assistance téléphonique au 1 888 942 6686 N de modèle 009 5206 4 GONFLEUR DE PNEUS NUMÉRIQUE À ENTRAÎNEMENT PAR ENGRENAGES ...

Page 10: ...Équipement de sport Petits articles gonflables pour la plage piscine APPLICATIONS DU GONFLEUR CARACTÉRISTIQUES 1 Ce gonfleur est destiné à être utilisé pour des applications haute pression notamment 1 5 5 6 6 7 7 8 8 9 9 10 11 13 12 4 2 3 UTILISATION ...

Page 11: ...uide fourni avec cet appareil Une mauvaise utilisation de l appareil peut causer des dommages matériels ou des blessures 2 AVERTISSEMENT Bouton de diminution de niveau de pression préréglée lb po2 Bouton de feu de détresse rouge Bouchon de tige de valve Adaptateur de valve Presta Bouton de la lampe de travail Panneau d affichage Poignée rabattable Fiche de 120 V maison Lampe de travail d avertissem...

Page 12: ...ar brancher le gonfleur à la source d alimentation souhaitée et en sélectionnant la source appropriée à l aide du sélecteur CA ARRÊT CC situé sur le panneau supérieur Le réglage de pression préréglée actuel est indiqué sur le côté gauche de l afficheur ACL sous l icône de manomètre réglé Réglage d une pression préréglée Le réglage d une pression préréglée peut être réalisé en appuyant sur les bouton...

Page 13: ...gonfleur s arrête Ce gonfleur garde en mémoire les réglages précédents et enregistre la dernière pression préréglée Par exemple si la pression préréglée est de 35 lb po le gonfleur garde en mémoire cette valeur pour la prochaine utilisation du gonfleur Avant d atteindre la pression désirée le gonfleur peut être arrêté manuellement en appuyant sur le bouton Marche Arrêt Pour éviter toute surchauffe et t...

Page 14: ......

Page 15: ... 15 minutes après 10 minutes de fonctionnement en continu Cycle de fonctionnement maximum 40 à 35 lb po Ne touchez pas le mandrin de valve en métal les adaptateurs ni la fiche de 12 V pendant ou immédiatement après l utilisation puisqu ils peuvent être chauds Laissez le gonfleur refroidir à température ambiante avant de le manipuler RISQUE D EXPLOSION Ne gonflez pas trop les objets Un gonflage excessi...

Page 16: ...s Nº de modèle 009 5206 4 Tension de fonctionnement 12 V CC ou 120 CA Pression max 120 lb po Fusible 15 A Cycle de service activé 10 minutes déactivé 15 minutes Accessoires adaptateurs haute pression 3 pièces bouchon de tige de valve de rechange fusible de rechange de 15 A FICHE TECHNIQUE PROTECTION DE L ENVIRONNEMENT Dans un produit à double isolation deux systèmes d isolation sont fournis au lie...