11.2 The analog Display with pointer
Depending on the model, the device shows rpm or ground speed. The models with the ground
speed scale have to have the value of Damp at 9 in the MOTOR setup parameter. The value of
SCL has to be 10K.
Models with rpm meter have to have their scale set to 0–8.000 rpm, 0–10.000 rpm, or 0-14.000
rpm resp., this has to be preset at the SCL value in the setup. Additionally, the vehicle-specific
parameter InpE has to be set.
If your analogue indicator is oscillating strongly, another rpm input filter InpF and or a different
indicator dampening factor DAMP should be chosen in the setup.
At start-up, the indicator moves to the stop pin. This calibrates the needle. Turning off the on-board
power supply while the engine is running (key switch), the indicator freezes at the rpm value last
displayed. This is perfectly normal for an instrument driven by a stepping motor and not a
malfunction. If this is an optical nuisance to you, you could turn off the engine with the kill switch
and interrupt the on-board power supply only afterwards.
11.2.1 RPM Limit Display by the Red Warning LED
The red LED (right side triangular symbol) blinks when a rpm value preset in the setup is reached
(refer to FLASH). The preset rpm value also controls the external gear shift flash output. The
flashing can be set to continuous light (refer to FIM).
11.3 Read-out on the LC-Display
11.3.1 Selecting Readouts on the LC-Display
The LC-Display has two lines. The display value of the first line can not be altered.
Push-button level 1 toggles between sensor values on the second line. Available display values are
determined by the preset chosen in the (SCREEN) setup.
11.3.2 The Ground Speed Display (km/h or mph)
Models with rpm scale permanently show the actual ground speed in the top line of the LCD. The
measuring range ranges from 0-350 km/h. Ground speed can also be displayed im miles (mph).
These settings can be changed in the setup (refer to SEL).
Models with ground speed scale show the current speed on the dial. Above a speed of 190 km/h
the speed value is shown on the first line of the of the LC display (instead of the day trip value). If
ground speed drops below 180 km/h or mph, the display switches back to the day trip meter.
11.3.3 The Day Trip Meter (km oder mi)
After start-up, the rpm scale model shows the day trip value in the second line. This value displays
the day trip total in the range from 0 to 999.99 km or mi (delete by push-button level 2).
11.3.3 The Total Distance Meter (km oder mi)
The total distance meter displays the total distance covered since first use of the instrument. This
value is kept even if the on-board power supply is switched off. It can be reset to 0 via the special
subitem "RESET/ALL" in the setup. The start-up value can also be preset in setup (ODO2set).
11.3.5 The Trip Time Meter (hh:mm:ss)
The trip time meter determines the actual driving time, since counting stops when the vehicle
comes to a stop. Road time is established to the second up to a time span of max. 99 hours and
59 minutes (delete by push-button level 2).
11.3.6 On-Board Voltage
This value represents the actual on-board voltage in the 9-18V range.