Installation
1-46 Manual # 42-02-2P26
Serial Car Call Board
The MC-CPI-2 board, mounted in the car operating panel, converts the discrete closures from
the panel buttons and switches to serial data for the CAN bus. Unused spare inputs to and out-
puts from these boards are set to NOT USED at the factory. If a CPI-2 board is replaced in the
field or if controller software is upgraded, it is very important to check programmable CPI-2
board inputs and outputs and verify unused connections are set to NOTUSED. The CPI-2 board
is also responsible for landing system control. For additional information, please refer to
Installation Instructions
1. Turn the power off at the main disconnect.
2. Mount the MC-CPI-2 board(s) inside the COP using the supplied hardware and provid-
ing sufficient clearance for the components. Verify board address,
3. CAR CALL indicator LEDs or lamps must be powered from the CC24V supply. Other
lamps, PIs, and buzzers must be powered from the 24V supply. Button contacts are gen-
erally connected to Common and to their specific I/O terminal.
4. Refer to the job prints to wire the MC-CPI-2 board.
Figure 1.2 MC-CPI-2 Serial Car Operating Panel Board