Configuration and Troubleshooting
2-26 Manual # 42-02-2P26
GSB
Secondary gate switch monitor to PLD
HAPS
Hydraulic Auxiliary Power Supply (MCE APS product for hydraulic elevators)
HC
Hall Call
HCF
Hall Call Front
HCT
Hall Call Time. Defined time for doors to remain open @ SPA DIAG > Door Dwell Timers
HDB
From ON position of switch used to bypass hoistway doors. Also places car on inspection
simultaneously. Hoistway Door Bypass signal to Safety Processor B @ SPB DIAG > SPB
Inputs
HDBO
From OFF position of switch used to bypass hoistway doors. Used for monitoring switch.
Hoistway Door Bypass OFF @ SPB DIAG > SPB Inputs
HDBOB
From OFF position of switch used to bypass hoistway doors. Used for monitoring switch.
Hoistway Door Bypass OFF B @ SPB DIAG > SPB Inputs
ICEN
In Car Inspection Enable @ System IO > System Inputs
ICPD
In Car Inspection push button down @ System IO > System Inputs
ICPU
In Car Inspection push button up @ System IO > System Inputs
ICTD
Inspection Cartop down button @ System IO > System Inputs
ICTU
Inspection Cartop up button @ System IO > System Inputs
IN1H
Programmable 24VDC active high input. Seismic (SS) or Counterweight (EQH) input.
IN2H
Programmable 24VDC active high input. Seismic (SS) or Counterweight (EQH) input
INA
Inspection, Access. Hoistway access enable switch input @ System IO > System Inputs
INAO
Access enable input from Safety Processor A
INCP
Inspection Car Panel @ System IO > System Inputs
INCPO
Inspection Car Panel input from Safety Processor A
INCT
Inspection, Cartop @ System IO > System Inputs
INCTD
Inspection Cartop Down input
INCTO
Inspection Cartop input from Safety Processor A
INCTU
Inspection Cartop Up input
IND
Independent service input, @ SYSTEM IO > PROGRAMMED INPUTS
IND SERV
Independent Service
IP
Internet Protocol
LLI
Light Load Input. Input from load weigher @ System IO > Programmed Inputs
LOP
Landing Operating Panel
LOPM
Loss Of Power input to Safety Processor B from SCE-UPD board
LOT
Lobby Open Dwell Time. Defined time for doors to remain @ SPA DIAG > Door Dwell Times
MAIN CLOCK
Main Clock @ PLDDIAG > PLD Inputs
MBRE
Monitor for low side solid state driver for brake contactor @ PLD > PLD Inputs
MDRE
Monitor for Drive Enable (output from controller)
MC-CPI-2
The serial car panel interface board
MEB1 2
Monitor for low side solid state driver for EB1/2 to PLD
MEB3 4
Monitor of solid state driver for EB3/4 @ SPB DIAG > SPB Inputs Car stop bypass)
MLT
Motor Limit Timer (anti-stall) @ ACTION INFO > Prohibit Run/Start Due to
MPME
Monitor for PM solid state driver for Up Fast valve @ PLD DIAG > PLD Inputs
MPSBR
Brake contactor output monitor @ SPA DIAG > SPA Inputs
MRDN
Machine Room DOWN (inspection direction button) @ PLD DIAG > PLD Inputs
MREN
Machine Room Enable (inspection enable button) @ PLD DIAG > PLD Inputs
Table 2.4 Acronym Descriptions and Memory Locations
Acronym
Description and Memory Location