Set Up for Construction Operation
2-35
2
Motion 4000
LF.78
Brake drop delay. Time motor will hold full current
and control after direction inputs drop.
sec
0.00 - 3.00
0.50
0.50
LF.79
Current hold time. Delay in turning off the drive
(Delay to turn OFF the motor current after direc-
tion is dropped and LF.78 has expired)
sec
0.1 - 0.5
0.3
0.3
Diagnostic Parameters (Read only)
LF.25
Estimated gear ratio
1
LF.80
Software version
-
LF.81
Software date
-
LF.82
X2A input state
-
see tables
in F5 Drive
Manual
LF.83
X2A output state
-
LF.86
Operation mode
-
LF.87
Actual inverter load (100% = rated load)
%
LF.88
Motor command speed
rpm
LF.89
Actual motor speed
rpm
LF.90
Actual elevator speed
ft/m
LF.93
Phase current
A
LF.94
Peak phase current
A
LF.95
Actual DC voltage
V
LF.96
Peak DC voltage
V
LF.97
Actual output frequency
Hz
O.LF.98 Last error
-
US Parameters
US. 1
Password: With different passwords different
parameter groups can be accessed for advanced
programming.
-
-
-
-
US. 3
Load defaults: Select LoAd and press ENTER to
cause all LF parameters to be reset to drive
default values.
-
LoAd
-
US. 4
Load configuration: Select LoAd and press ENTER
to load the configuration selected in US.10.
-
LoAd
-
US.10
Select configuration: Selects the drive mode.
ICLSd - Close loop induction
I9LSS = Closed loop induction gearless
PCLSd = Closed loop permanent magnet (PM)
P9LSS = Closed loop PM gearless
-
ICLSd
I9LSS
PCLSd
P9LSS
-
*
US.34
Analog Pattern Gain
-
0.01-20.0
1.0
US. 35
Reference Splitting: This function creates a slope
between two successive serially transmitted speed
values. This parameter should be adjusted for a
time double the actual serial update rate of the
speed command
Note:
Program to 40 msec for M4000
mSec 0 –127 mSec
0.0
40
* Parameters are motor / machine / job dependent.
** Recommended but field adjustable.
*** The value is automatically calculated from the motor data or other parameter values.
Parameters for Drive Software Version (LF 80 Drive Software = 1.61 with LF.81 date code = 2801.9 or later)
or (LF 80 Drive Software = 1.71 with LF.81 date code = 704.0 or later.
Table 2.4 TorqMax F5 Parameters
Display
Parameter Description
Unit
Range
Default
Factory
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...