LF.41
Leveling speed (Not used, must set to 0)
fpm
0 - 25
0.0
0.0
LF.42
High speed (Not used, set from 0 to LF.20)
fpm
0.0 - LF.20
0.0
0.0
LF.43
Inspection speed (Not used, must set to 0)
fpm
0.0 - 150.00
0.0
0.0
LF.44
High leveling speed (Not used, must set to 0)
fpm
0.0 - LF.20
0.0
0.0
LF.45
Earthquake Speed (Not used, must set to 0)
fpm
0.0 – 150.0
0.0
0.0
LF.46
Emergency Pwr Speed (Not used, must set to 0)
fpm
0.0 - LF.20
0.0
0.0
LF.47
Intermediate speed (Not used, must set to 0)
fpm
0.0 - LF.20
0.0
0.0
LF.49
Overspeed function Test (N/A for drive SW Version
1.61)
fpm
1- 2400
100
100
0.LF.50 Profile 0 - Starting jerk (not used)
ft/s
3
OFF
0.LF.51 Profile 0 - Acceleration (not used)
ft/s
2
OFF
0.LF.52 Profile 0 - Acceleration jerk (not used)
ft/s
3
OFF
0.LF.53 Profile 0 - Deceleration jerk (not used)
ft/s
3
OFF
0.LF.54 Profile 0 - Deceleration (not used)
ft/s
2
OFF
0.LF.55 Profile 0 - Approach jerk (not used)
ft/s
3
OFF
1.LF.50 Profile 1 - Starting Jerk (not used)
ft/s
3
OFF
1.LF.51 Profile 1 - Acceleration (not used)
ft/s
2
OFF
1.LF.52 Profile 1 - Acceleration jerk (not used)
ft/s
3
OFF
1.LF.53 Profile 1 - Deceleration jerk (not used)
ft/s
3
OFF
1.LF.54 Profile 1 - Deceleration (not used)
ft/s
2
OFF
1.LF.55 Profile 1 - Approach jerk (not used)
ft/s
3
OFF
2.LF.50 Profile 2 - Starting jerk (not used)
ft/s
3
OFF
2.LF.51 Profile 2 - Acceleration (not used)
ft/s
2
OFF
2.LF.52 Profile 2 - Acceleration jerk (not used)
ft/s
3
OFF
2.LF.53 Profile 2 - Deceleration jerk (not used)
ft/s
3
OFF
2.LF.54 Profile 2 - Deceleration (not used)
ft/s
2
OFF
2.LF.55 Profile 2 - Approach jerk (not used)
ft/s
3
OFF
LF.56
Stop jerk (not used)
ft/s
3
OFF
LF.57
Speed following error (0 = off, 1 = on,)
1
off, on
1
1
LF.58
Speed difference
%
0 - 30
10
10
LF.59
Trigger time speed difference: Following error
timer
sec
0.0 -1.0
1.0
1.0
LF.61
Emergency operation mode. If using an MCE
TAPS, (Traction Auxiliary Power Supply) this must
be set to di1.
Off, SPd1,
SPd2, SPd3,
di1
off
off
(di1 if TAPS
used)
LF.67
Pre-torque gain
-
0.25 - 2.00
1.00
1.00
LF.68
Pre-torque offset
%
-100.0 - 100.0 0.00
0.00
LF.69
Pre-torque direction (0, 1 = +V, -1 = -V)
1
0, 1, -1
1
1
LF.70
Speed pick delay (Delay to turn on DRO)
sec
0.0 - 3.0
0.30
0.30
LF.71
Brake pick delay
sec
0.0 - 3.0
0.05
0.05
LF.76
Encoder resolution multiplier
2 for incremental encoder
8 for Sin/Cos, EnDat or Hiperface encoder
1
0 - 13
2
LF.77
Absolute encoder position (measured)
1
0 - 65535h
0
*0
Table 2.4 TorqMax F5 Parameters
Display
Parameter Description
Unit
Range
Default
Factory
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...