User Interface
4-66 Manual # 42-02-2P24
MPI Diagnostic Menu
These diagnostics allow you to view car motion parameters (speed/distance) as the car moves
through the hoistway. This information in turn will help you make ride adjustments or trouble-
shoot ride issues.
The initial screen will show either METRIC or ENGLISH units.
1. To switch between Metric or English units, press N once. (Pressing N a second time will
back you out of the menu.)
2. With the desired measuring units displayed, press S to begin diagnostics display.
The initial display is for MPI-A (Processor A on the MPI board), address zero. This address dis-
plays the number of floors served — two in this example.
3. To select the parameter to display, use the S button to move between digits (processor A,
B, or C or address positions 0000 - 9999) — the selected digit will flash — and the Plus
(+) or Minus (-) buttons to change the value of the selected digit.
For example, to display to speed recorded by MPI Processor B the last time the car passed the
Down Normal Terminal switch S2, select MPI-B, address 0019.
• To find the address of the data you want to display, check the following tables.
• MPI-A and MPI-B independently collect information from the Elgo positioning sen-
sors. The information they display per address should usually match. However, if you
are displaying position information, you need to factor in that the sensors they moni-
tor in the Elgo sensor head are 160 mm (6.3 inches) or 230 mm (9.05 inches) apart.
• MPI-C collects information from the drive/motor/encoder.
As soon as you select an address, the information stored there is displayed.
Metric or English units may be displayed
1.01 meters per second (Metric)
or
200 feet per minute (English)
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...