F3: System Mode
4-57
4
Motion 4000
Activating the Passcode
With the Passcode
Request menu displayed, press S. If Passcode Request Oper-
ation is not activated, the following display appears:
• Press S to toggle from “NO” to “YES.”
• Press N with “YES” displayed to activate Passcode
Request Operation and exit this screen. With Passcode
Request Operation activated, the passcode must be entered in order to run the car on any
mode of operation other than Inspection.
• Press N with “NO” displayed to exit with Passcode Request inactive.
Load Weigher Thresholds
Analog load weighers provide a signal that corresponds to the load in the car. This value is used
to make dispatching decisions. Load thresholds are user-programmable.
Note
This section is not applicable to discrete input load weighers.
Please refer to “Load Weigher” on
or to manufacturer instructions for the installed load weigher.
• LIGHT LOAD WEIGHER (LLW)
• Used to define the load at which the number of car calls will be limited (anti-nuisance).
If the programmed number of car calls is exceeded, all car calls are canceled.
Example: LLW=20%. If the load in the car is less than 20%, the computer will only
allow a certain number of car calls to be registered as defined by the parameter LIGHT
LOAD WEIGHING? / LIGHT LOAD CAR CALL LIMIT in the EXTRA FEATURES
MENU OPTIONS. If the limit is set to a value of three, the computer will only allow
three calls to be registered if the load is less than 20%. If a fourth call is registered, all
car calls will be canceled.
• DISPATCH LOAD WEIGHER (DLW)
• Used to define the load at which the lobby landing door timer will be reduced so that
the doors may begin closing sooner, limiting the number of boarders. This threshold
should be set to a value (defined in many specifications as 60%) at which it is appropri-
ate to initiate the process of moving the car out of the lobby.
• HEAVY LOAD WEIGHER (HLW)
• Used to define the load value at which additional hall calls should be bypassed to avoid
overloading the elevator.
• OVERLOAD WEIGHER (OLW)
• Used to define the load at which it is considered unsafe to move the elevator. When
this threshold is exceeded, the car will remain at the floor with doors open and typi-
cally sound a buzzer or otherwise indicate that the car is overloaded.
Summary of Contents for Motion 4000
Page 20: ...xiv Manual 42 02 2P24 5 20 13 ...
Page 38: ...Motion 4000 Traction Elevator Control 1 18 Manual 42 02 2P24 ...
Page 178: ...Final Adjustments 3 56 Manual 42 02 2P24 ...
Page 322: ...User Interface 4 144 Manual 42 02 2P24 ...
Page 391: ...PC Board Quick References 5 69 5 Motion 4000 Figure 5 11 Example MC CPI Wiring ...
Page 439: ...Customer Notations A 27 A Motion 4000 Customer Notations Table A 4 Customer Notation Area ...
Page 444: ...Appendix A 32 Manual 42 02 2P24 ...