1.5 Operation

When using the biological microscope, please pay attention to the following safety instructions:

• If it is used for any purpose other than the specified ones, including any individual component or part,  

the manufacturer will not take any responsibility.

• After-sales service or repair done by unauthorized personnel will void the warranty.
• Anyone who uses the instrument should receive instruction on the proper handling of the instrument and safety 

practices for microscopy. The biological microscope shall be placed only on a firm, flat workbench for operation.

• Since the biological microscope is a precision instrument, improper operation will impair or spoil its performance.
• The power unit is integrated in the main unit of the biological microscope: the grid supply voltage is within 

100-240V~50Hz.

The biological microscope must be connected only to the normal power socket with  
a grounding terminal. Any extension cord without ground protection is not allowed to avoid 
failure of the protection function.

If there is any electrical failure (of the fuse system, ground protection or transformer), 
turn off and unplug the unit immediately. Make sure the microscope is set aside so it will 
not be used again and contact the Motic service department or a Motic microscope repair 
agency to have it repaired.

Please be sure to turn off the power before opening the instrument to replace  
LED illuminator or replace the fuse! Only use a fuse for the rated current.

Safety instructions for the use of immersion oil.
• Immersion oil is irritating to skin; avoid contact with skin, eyes and clothing.
• Skin contact: wash with soap and plenty of water until the immersion oil  

is completely removed.

• Eye contact: flush immediately with plenty of water for at least 5 minutes.  

If irritation persists, seek medical advice.

• Dispose of immersion oil properly. Do not discharge into surface water or sewage.

The biological microscope is not equipped with any special device to protect against corrosive, latent infective, 
toxic, radioactive or other hazardous samples. Therefore, when examining any such sample you must comply with 
the relevant laws and regulations, in particular the provisions related to accident prevention.

Summary of Contents for RED 200 Series

Page 1: ...Motic Incorporation Ltd Instructions Manual English RED200 SERIES...

Page 2: ......

Page 3: ...warranty 07 2 Instrument description 08 2 1 General views 08 2 2 Part names 09 2 3 Application 12 2 4 Instrument and its major features 12 3 First time use operation 13 3 1 First time use 13 3 2 Opera...

Page 4: ......

Page 5: ...g to the EN 61010 1 2001 Safety Requirements for Electrical Equipment for Measurement Control and Laboratory Use 1 3 Unpacking transportation storage The original shipping container a foam box in a fi...

Page 6: ...f the protection function If there is any electrical failure of the fuse system ground protection or transformer turn off and unplug the unit immediately Make sure the microscope is set aside so it wi...

Page 7: ...found notify the manufacturer immediately Upon receipt of the Notification of Defect as described above the manufacture is responsible to solve the problem either by repairing the defective instrumen...

Page 8: ...8 RED200 SERIES 2 1 General Views 2 INSTRUMENT DESCRIPTION RED230 233 Eyepiece Trinocular Head Binocular Head 10x 20 10x 18 RED220 223...

Page 9: ...ry distance scale 8 Condenser fastening screw 3 Binocular head 9 Body tube lock screw 4 Quadruple Nosepiece 10 Arm and base a single piece 5 4X 10X 40X 100X objectives 11 Stage adjustment knob X axis...

Page 10: ...ES 13 Condenser focus knob 17 Condenser aperture diaphragm adjustment handle 14 Coarse and fine focus knob 18 Collector RED230 RED233 15 Brightness control 16 Condenser RED230 RED233 RED230 RED233 13...

Page 11: ...11 RED220 RED223 19 Condenser RED220 RED223 20 Collector RED220 RED223 19 20...

Page 12: ...t Cord hanger at the back to accommodate power cable convenient and practical Coaxial coarse and fine focus adjustment with coarse focus tension control 75mm x 30mm mechanical stage with slide clips Q...

Page 13: ...lugging in keep in mind that the working voltage of the biological microscope shall be the same as the supply voltage Figure 1 Turn on the power switch at the back of the base Figure 2 Note Make sure...

Page 14: ...nation The RED200 Series biological microscope has been set already before delivery and can be adjusted as follows Put the specimen on the stage and fix it with the slide clips Note The thickness of t...

Page 15: ...of the field of view At this time stopping the field diaphragm image just short of the maximum field of view may be convenient for centering Adjust and centre the field diaphragm so that it is just ou...

Page 16: ...icroscope before making any modifications Figure 10a Figure 10b 1 2 3 3 2 Replace the objective Lower the stage all the way with the coarse focus knob Rotate the nosepiece to move the objective to be...

Page 17: ...eads can be con nected to the photo port of the biological microscope using an adapter a 0 5X adapter is supplied Screw the adapter onto the camera Loosen the setscrew of the photo port and remove the...

Page 18: ...o the slot Rotate the nosepiece to lock into the slot Condenser is not set properly Set the condenser properly Aperture iris diaphragm is not set accu rately Set the aperture iris diaphragm accurately...

Page 19: ...rage Permissible environment temperature Permissible relative humidity 10 40 C Below 31 C max humidity is 80 at 40 C linearly decreases to 50 Operation Permissible environment temperature Permissible...

Page 20: ...nser fixed K hler 140x135mm 75x30mm On the right On the right On the left of movable clip Used for 4X 100X objectives Binocular tube 30 20 Length of mechanical tube Maximum field number Hinge type int...

Page 21: ...21...

Page 22: ...ouse 311 Gloucester Road Causeway Bay Hong Kong Tel 852 2837 0888 Fax 852 2882 2792 Motic Spain S L U Spain Pol Ind Les Corts C Les Corts 12 08349 Cabrera de Mar Barcelona Spain Tel 34 93 756 6286 Fax...

Reviews: