Mosmatic TYR-f Assembly & Service Manual Download Page 1

T

D

-

8

14

00

E

©

 M

O

SM

A

T

AA

IC

A

G

03

.1

0

.2

0

11

S

ub

ject to chan

g

e without notic

e

TYR-f

No. 81.400

Assembly and Service instructions

Duct cleaner *fixed*

Assembly instructions

 

Assembly and connection

1.  

Screw the nozzles (a / accessory) into the pipes of the distributor-arm (b).

2.  

Turn the adjustable rotor guard (c) to the desired operating position and  

 

secure with nut (h) tightly.

3.  

Fasten tightly the high pressure hose or the high pressure pipe   

 

connection (d) of the swivel (e) coming from the high pressure pump.

 

Installation to the TYR Mobile (accessory)

1.  

Install the duct cleaner with the swivel (e) to the support (f) of the 

 

TYR mobile (g / accessory) and tighten it by hand. 

 

 

 

Secure the rotor guard (c) with the nut (h) to the support (f).

2.  

Adapt the TYR mobile (g / accessory) to the object to be cleaned, by 

 

adjusting the frame (i) and the support (f) with the bolts (j).

3.  

Fasten tightly the high pressure hose or the high pressure pipe    

 

connection (d) of the swivel (e) coming from the high pressure pump.

 

For your own safety

Read all instructions before the initial operation. Check their proper 
condition and that they operate safely.

Always use protection gear when using products connected to high 
pressure.

Never direct any high pressure water-jet at humans, animals or electric 
installations.

Before any maintenance or nozzle-change, turn off the high pressure 
water supply, e.g.: turn off and secure the power switch.

After turning off the system, allow all self propelled equipment to come 
to a complete stop before handling.

Safety regulations and guidelines (Accident Prevention Rules) from the 
manufacturer of your high pressure cleaner are applicable.

Nozzle installation according to Nozzle manufacturer.

Do not run the unit if spray-arm is out of balance or bent, damage to the 
swivel will result.

No modifications to the unit are permitted.

The equipment may be installed and used only by particularly trained 
technical personnel. 

Service instructions

 

Exchanging the swivel

1.  

Hold the coupling (k) on the swivel (e) with a spanner and remove  

 

the distributor-arm (l) by hand.

2.  

Loosen the nut (h) with a spanner then turn out the swivel (e) from 

 

the rotor guard (c).

3.  

Implement the procedure for the installation of the new swivel (e)  

 in 

reverse 

order.

 Exchanging 

the 

distributor-arm

1.  

Hold the coupling (k) on the swivel (e) with a spanner and remove 

 

the distributor-arm (l) by hand.

2.  

Implement the procedure for the installation of the new distributor- 

 

arm (l) in reverse order.

 

Exchanging the rotor guard

1.  

Hold the coupling (k) on the swivel (e) with a spanner and remove 

 

the distributor-arm (l) by hand.

2.  

Disconnect the nut (h) with a spanner then turn out the swivel (e) 

 

from the rotor guard (c).

3.  

Implement the procedure for the installation of the new rotor 

 

guard (c) in reverse order.