15
4 MAINTENANCE
Moser Baer Photovoltaic modules require very little maintenance, following is
recommended to ensure optimum performance.
1.
In view of the tilt angle of the PV modules , normal rainfall is sufficient to keep the
module glass surface clean in most weather conditions. However, if dirt build up
becomes excessive, clean the glass surface only with a soft cloth or sponge
using water.
2.
A mild non abrasive cleaning agent can be used for stubborn dirt. Do not use high
pressure water spray or chemicals to clean the module.
3.
In order to ensure proper operation, please check all wiring connections,
condition of the insulation and mechanical connections every six months.
4.
Observe the maintenance instructions of all components used in the systems
such as support frames, inverters, battery and charge controller etc
(Typical Electrical Parameters)
Unit
AHFP
BAAP
BCAP
BDAP
BGFP
Nominal Power at STC, Pmax
[W]
75
100
120
130
170
Power tolerance at STC (min / max)
%
±3%
Voltage at Pmax, Vmp
[V]
17.2
22.93
17.4
28.5
36.5
Current at Pmax, Imp
[A]
4.51
4.51
7.12
4.64
4.7
Open circuit voltage, Voc
[V]
21.78
29.04
21.5
36.05
43.26
Short Circuit Current, Isc
[A]
4.8
4.8
7.6
5.05
5.1
NOCT
(±2)°C
47
47
47
47
47
Maximum System Voltage (IEC/UL)
V DC
1000/600
Temperature Coefficient of Pmax
%/K
-0.43
Temperature Coefficient of Voc
%/K
-0.344
Temperature Coefficient of Isc
%/K
0.11
IP Protection Level
IP 65
Absolute Maximum Rating
Operating Temperature
°C
-40 to +85
Mechanical Parameters
Cell Type
mm
Multi Crystalline Cells
Cell Size
Inch
5
5
6
5
5
No. of Cells (Matrix)
nos
36
48
36
60
72
Module Overall Dimensions (A)
mm
839
1095
1027
1353
1606
Module Overall Dimensions (B)
mm
810
813
999
813
806
Module Overall Dimensions (C)
mm
40
40
40
40
40
Weight ( Approx )
kg
7.5
10
11.5
13.3
15
2
Maximum Wind Load (Static load front & back {e.g. wind})
Pa
2400 (50 lbs/ft )
Resistance against Hail ( Hailstone Impact )
25 mm ice ball at 23 m/s at 11 impact location
Max series Fuse
Amp
7.5
7.5
10
7.5
7.5
2
Note: STC : Irradiance 1000 W/m , cell Temperature at 25°C & AM 1.5 spectrum
- Module available in each category are within ± 10% power range.
- Refer product data sheet of particular category of module on Moser Baer web site for detailed information.
5 MODULE SPECIFICATIONS