Morphy Richards IB70036 Instructions Manual Download Page 1

Fusion bagless cylinder vacuum cleaners

Please read and keep these instructions

www.morphyrichards.co.uk

getting the best from your 
new cleaner...

If your cleaner is not picking up as well as it 
should, please check

• Filters

It is important that the airbox and filters are cleaned regularly to
allow air through the appliance. Tap to remove dust, the filter can
also be washed in warm water and left to air dry.

IMPORTANT - Ensure filter is totally dry before refitting into
machine.

• Blockages

Check the hose, handle and tools for blockages.

• Overheating protection

The cleaner automatically cuts off in the event of overheating
caused by blocked hoses / filters. Remove plug, clear blockage
and allow 15 minutes for the cleaner to automatically reset.

Summary of Contents for IB70036

Page 1: ...e cleaned regularly to allow air through the appliance Tap to remove dust the filter can also be washed in warm water and left to air dry IMPORTANT Ensure filter is totally dry before refitting into machine Blockages Check the hose handle and tools for blockages Overheating protection The cleaner automatically cuts off in the event of overheating caused by blocked hoses filters Remove plug clear b...

Page 2: ...be replaced Do not attempt this task yourself contact Morphy Richards using the replacement parts number on the front of this leaflet The appliance must never be left running when unsupervised This vacuum cleaner is intended for domestic use only Misuse or use for commercial or any other purpose will render the guarantee invalid Always disconnect the appliance from the mains supply after use or pr...

Page 3: ... control On off foot switch Cable rewind foot switch Exhaust filter cover Carrying handle Tube park on underside of cleaner  Tube standby slot Accessories you should have Ê Suction hose with 360 swivel connector Á Handle with airflow control Ë Floor nozzle È Combination telescopic metal tubes Í Upholstery tool Î Crevice tool Ï Furniture brush Ë Ê Â È Î Í Ï fi ...

Page 4: ... indicated and pull or push the tube to the desired length Floor nozzle Ë This nozzle is suitable for general purpose cleaning on a wide variety of floor coverings Operation The cable should always be fully withdrawn before plugging into an electrical socket Switching on Ensure that the electronic suction power control is set to minimum slider to the left Press foot pedal to start the motor 4 È ...

Page 5: ...cool down The vacuum cleaner cuts out automatically when The floor nozzle or tubes become blocked Using the vacuum cleaner with a full air box The motor protection filter is very dirty The exhaust filter is very dirty Rectify the cause of the cut out and do not use for 15 minutes to allow the motor to cool M IN M AX Power setting Application Curtains and delicate fabrics Textiles and upholstery Fl...

Page 6: ...shelves etc pushes onto the crevice tool Tube standby During short breaks in cleaning the tubes can be held in an upright standby position whilst you move furniture for instance CAUTION Ensure that the appliance is never left unattended whilst it is switched on After vacuum cleaning 1 Switch off the vacuum cleaner 2 Unplug from the mains 3 Use a hand or foot to operate pedal to rewind the cable CA...

Page 7: ... compartment release button indicated by arrow 1 and lift up the dust compartment lid arrow 2 Holding the handle on the airbox lift upwards and remove the airbox from the machine Take the airbox to the dustbin Unclip the airbox lid as shown from the handle side first Place the lid to one side and empty the contents of the airbox into the dustbin 7 ...

Page 8: ... DRY BEFORE REPLACING INTO THE MACHINE Replacement filters can be purchased from our Replacement Parts Helpline Number 0870 167 6635 To reassemble insert the filter into the airbox and twist clockwise 1 4 of a turn Replace the airbox lid by locating the two tabs on the underside of the airbox opposite side of handle into the lid and clip into place Slide the airbox back into the dust compartment e...

Page 9: ...the flap on the filter cassette 2 Take out the micro hygiene filter 3 Wash in warm water and leave to air dry DO NOT USE DETERGENTS 4 Replace the dry filter and close the filter cassette 5 Insert the airbox and close the dust compartment cover Recommendation The micro hygiene filter should be cleaned when you have emptied the airbox 5 times Important Ensure the filter is completely dry before rein...

Page 10: ...t air filter upwards and remove 3 Wash in warm water and leave to air dry DO NOT USE DETERGENTS 4 Replace the dry filter and close the cover Important Ensure the filter is completely dry before reinserting into the machine Replacement filters can be purchased from our Replacement Parts Helpline Number 0870 167 6635 Storage Tube park The vacuum cleaner can be stored in an upright position Rotate th...

Page 11: ...the underside of the floor nozzle clean vacuum it at regular intervals using the crevice tool Helpline If you have any difficulty with your appliance do not hesitate to call us We are likely to be more help than the store from where it was bought Please have the following information ready to enable our staff to help you Name of product Model number as shown on the underside of the appliance 11 ...

Page 12: ...ain your original till receipt or invoice to indicate the date of initial purchase To qualify for the 3 year guarantee the appliance must have been used according to the manufacturers instructions For example the filters must be cleaned regularly EXCLUSIONS Morphy Richards shall not be liable to replace or repair the goods under the terms of the guarantee where 1 The fault has been caused or is at...