PREPARATION BEFORE STARTING MASS PRODUCTION F-37
9-5
Contents of Display on the Load Monitor Screen
This section describes the contents of the information displayed on this screen.
<Monitor data display area>
The monitor data display area shows the present status of the machine.
Load values (%) of the axes being monitored are displayed in this area in bar graph and numeric
values.
Present load values are displayed in the column left to the bar graph with the maximum load
values displayed in the right side column.
<Group information display area>
The information of the group for which teaching or monitoring is presently executed is displayed.
It is not possible to set or change the values of WRN and ALM.
Item
Description
GROUP
The group number of the group for which teaching or monitoring is
presently executed is displayed.
STD (%)
The maximum load detected during the cutting of the specified group is
displayed.
In the teaching mode, the value displayed in this column is
updated whenever the maximum load value changes.
WRN (%)
The threshold level value to cause warning is displayed.
ALM (%)
The threshold level value to cause alarm is displayed.
Group
information
display area
Monitor data
display area
NOTE
NOTE