SETTING OF COORDINATE SYSTEM E-7
3
PREPARATION FOR SETTING THE COORDINATE SYSTEM
This section describes the operation to be carried out before setting the coordinate system.
1.
Set the shift amount (common value) and the X and Z values of the work offset amount
automatically read as a modal value to "0" on the WORK OFFSET screen.
The coordinate values X and Z of the No. 01 work coordinate system must be reset to "0"
because the G54 work coordinate system is read automatically when power is turned on.
2.
Carry out the zero return operation.
3.
Machine the datum plane (end face, external/internal face, etc.) in the workpiece.
<Operation procedure>
1)
Place the DOOR INTERLOCK key-switch in the
NORMAL
position.
2)
Close the front door.
3)
Place the PANEL key-switch in one of the positions
indicated below.
(ON)
(PANEL/EDIT)
4)
Press the HEAD CHANGE switch
(head 1) or
(head 2) to select the required turret.
NOTE
DOOR INTERLOCK
NORMAL
RELEASE
ON
PANEL
/EDIT
OFF
PANEL
2
1
HEAD CHANGE
1
2