OPERATION PANELS A-61
5-15
Coolant Switches [COOLANT]
The COOLANT switches are used to manually operate
the coolant.
1.
Close the front door before supplying the
coolant so that the coolant will not splash
out.
2.
The
(OFF) switches for turret 1 and
turret 2 are turned on or off simultaneously.
Switch
Function
When this switch is pressed, the indicator in the switch is lit and coolant is
supplied through the nozzles.
When the coolant ON M code is read during automatic operation (MDI, memory,
or tape mode), the indicator in the
(ON) switch is lit and coolant is
automatically supplied.
When this switch is pressed while coolant is being supplied, the coolant supply
stops and the indicator in the
(ON) switch goes off.
Pressing this switch for 1 second or more while coolant is not being
supplied causes the indicator in the
(ON) switch to blink and the
coolant off mode becomes valid.
In this state, the coolant is not supplied even if an M08 command is
executed.
<To cancel the blink state>
1.
Press the
(ON) switch.
The indicator in the switch lights and the coolant is supplied.
2.
Press the
(OFF) switch.
The indicator in the
(ON) switch goes off and the coolant is
not supplied.
COOLANT
ON
OFF
NOTE
ON
OFF
NOTE