OPERATION PANELS A-53
3.
Spindle speed setting switches
(increase) +
(decrease)
Pressing these switches together sets the override data to 100%.
When the power is turned on, the override value is automatically set to 100%.
The spindle speed does not exceed the maximum allowable spindle speed.
5-9-2
Spindle Override Meter [OVERRIDE]
The OVERRIDE meter indicates the spindle speed
override data set using the spindle speed setting switches
(increase) and
(decrease) (in the automatic
mode) and the spindle speed (in the manual mode).
When the power is turned on, 100% is displayed.
With the S type machines, the spindle speed
override data (for automatic operation) and the
spindle speed data (for manual operation) are
used in common to spindle 1 and spindle 2, and it
is not allowed to set different data for these two
spindles.
5-9-3
Spindle Neutral Gear Switch [SPINDLE NEUTRAL] (Transmission Specification)
The SPINDLE NEUTRAL switch, provided on the option
panel, is used to manually select the neutral position of
the spindle.
Switch operation is impossible with the PANEL
key-switch placed in the
(OFF) position.
1.
When pressing this switch while the spindle is stopped, the spindle is put in neutral and the
indicator in the switch is lit.
2.
When pressing this switch again while the front door is closed and the indicator in the switch
is lit, the spindle gear is returned to the previously selected gear position before neutral
position and the indicator in the switch goes off.
3.
When changing the operation mode from manual to automatic while the front door is closed
and the indicator in the switch is lit, the spindle gear is returned to the previously selected
gear position before neutral position and the indicator in the switch goes off.
Gear position is canceled when M02 or M30 command is executed before the spindle is
put in neutral by pressing this switch. In this state, the spindle gear is not returned to the
previously selected gear position before neutral position even if pressing the switch again
and changing the operation mode from manual to automatic.
NOTE
%
NOTE
SPINDLE NEUTRAL
NOTE
NOTE