OPERATION PANELS A-45
5-7
Status Indicators [STATUS]
The STATUS indicators are used to confirm the status of the machine.
The individual STATUS indicators light or blink in the following cases:
1.
When the machine is at the reference position for an intended operation.
2.
When the machine has stopped during an automatic operation.
3.
When an alarm has occurred.
Status indicator
Contents of Indication
The STATUS indicator
[ERR]
is lit or blinks if an alarm state is detected.
The STATUS indicator
[ERR]
is lit when a program error occurs.
The STATUS indicator
[ERR]
blinks when a machine error occurs.
If an alarm occurs, the corresponding alarm message is displayed on the
screen.
The STATUS indicator
[M00/M01]
is lit and the machine stops in the following
cases:
1.
When an M00 command (program stop) is read.
2.
When an M01 command (optional stop) is read while the optional stop
function is valid.
1.
The M01 command in a program is ignored when the optional stop
function is invalid, and the program proceeds to the next block
without halting.
2.
In a program, specify the M00/M01 command in an independent
block.
M00/M01
STATUS
MRDY
ERR
TRCL
X
Z
M02/M30
CHCL
STATUS
C
Y
2
C
Y
1
ERR
TRCL
M02/M30
M00/M01
STATUS
X
Z
HEADSTOCK 2 CHUCK CLAMP
B-AXIS ZERO POINT
<Operation panel>
<Option panel>
<S type>
<Turret 2>
ERR
NOTE
M00/M01
NOTE