A-30 OPERATION PANELS
5-6-3
Block Delete Switch [BDT]
When this switch is pressed, the indicator in the switch is
lit and the block delete function becomes valid.
When this switch is pressed again, the indicator in the
switch goes off and the block delete function becomes
invalid.
1.
The block delete functions (/2 to /9) are optional and whether each of the block
delete functions is valid or invalid is set on the OPERATION PANEL screen.
2.
The valid and invalid status of the block delete function changes simultaneously
when either of the block delete switches
provided for turret 1 and turret 2
respectively is pressed to change valid/invalid status.
<Block delete function>
The block delete function ignores the blocks preceded by a slash code [/ (/2 to /9)], and the
program advances to the next block without executing such blocks.
<When the block delete function is valid>
The block preceded by a slash code [/ (/2 to /9)] is ignored and the next block not containing the
slash code [/ (/2 to /9)] is executed.
<When the block delete function is invalid>
All blocks (even those preceded by a slash [/ (/2 to /9)]) are executed.