OPERATION PANELS A-25
5-6-2
Optional Stop Switch [OSP]
When this switch is pressed, the indicator in the switch is
lit and the optional stop function becomes valid.
When this switch is pressed again, the indicator in the
switch goes off and the optional stop function becomes
invalid.
<Optional stop function>
The optional stop function makes the M01 (optional stop) command written in a program valid.
This function is used to check the conditions of the cutting tool or to remove chips from the
machine during automatic operation and to check a program at each process of test cutting.
<When the optional stop function is valid>
In the optional stop mode, spindle rotation, coolant supply, and axis feed stop after the execution
of an M01 block.
To continue the interrupted operation, press the
(START) switch.
Specify the M01 command in an independent block.
<When the optional stop mode is invalid>
Any M01 command is ignored and the program is executed continuously.
5-6-3
Block Delete Switch [BDT]
When this switch is pressed, the indicator in the switch is
lit and the block delete function becomes valid.
When this switch is pressed again, the indicator in the
switch goes off and the block delete function becomes
invalid.
The block delete functions (/2 to /9) are optional
and whether each of the block delete functions is
valid or invalid is set on the OPERATION PANEL
screen.
<Block delete function>
The block delete function ignores the blocks preceded by a slash code [/ (/2 to /9)], and the
program advances to the next block without executing such blocks.
<When the block delete function is valid>
The block preceded by a slash code [/ (/2 to /9)] is ignored and the next block not containing the
slash code [/ (/2 to /9)] is executed.
<When the block delete function is invalid>
All blocks (even those preceded by a slash [/ (/2 to /9)]) are executed.
OSP
NOTE
BDT
NOTE