Item
Status
Cause
Reference Items/Recovery Procedures
1
Pressure does
not rise
Low oil level in tank
“Replacing Oil” (page 94), “Checking Oil Level/
Replenishing Oil” (page 94)
Suction strainer clogging
“Cleaning Suction Strainer and Tank” (page 96)
a
b
1.
2.
3.
Hydraulic pressure setting is 3.5 MPa
(NL1500/2000) or 4.0 MPa
(NL2500/3000)?
Hydraulic oil level sufficient?
Oil leakage visible?
Cleaning Suction Strainer
Replenishing Hydraulic Oil
Tighten connections.
If hose is damaged, contact the
Mori Seiki Service Department.
If oil is leaking from pump, contact
the Mori Seiki Service Department.
If alarm condition not released, contact the Mori Seiki Service Department for assistance.
No
Yes
No
Yes
Switch may be malfunctioning.
Contact the Mori Seiki Service Department
for assistance.
Yes
No
Recovery
Recovery
No Recovery
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......