ໃੵоɁʒʳʠʵ
MALFUNCTIONS AT MAIN POWER ON
172
3-3
ʓɬᩒᩐɥᚐȶȹɕ
‘
ʓɬɥˢ࣊ᩒᩐȪȹ˩Ȩȗ
’
Ɂʫʍʅ˂ʂȟțȽȗ
‘OPEN THE DOOR THEN CLOSE’ Display does Not Disappear when Door Opened/Closed
ʓɬʷʍɹᚽᏚȾͷɜȞɁႱࢠȟȕɞȻᐎțɜɟɑȬǿ͏˩
ɁᬱᄻɥᆬᝓȪȹႱࢠȟȽȗȻȠɂǾࣷᇋɿ˂ʝʃᩌȾȧ
ᣵፅȢȳȨȗǿ
The primary cause is a door lock device malfunction. If unable
to determine the cause after the following confirmation, contact
the Mori Seiki Service Department for assistance.
ᴹᆬᝓ̜ᬱᴻ
<Confirmation>
1.
ʓɬʷʍɹᚽᏚɁ͇ȤͱᏚȾȭɟǾəȟɒȟȽȗȞ
1.
Check the door lock mounting position for gaps or warping.
2.
ʓɬʷʍɹᚽᏚɁɷ˂ȟᆍૺȪȹȗȽȗȞ
2.
Check for door lock device key damage.
3.
ʓɬʷʍɹᚽᏚɁɷ˂ɁоɝщնɂඩȪȗȞ
3.
Check the door lock device key locking action.
3-4
EX0451
ȝɛɆ
EX0457
ȟ᚜ᇉȨɟȲȻȠ
When EX0451 or EX0457 are displayed
ɿ˂ʦɬʽʡᴬʃʞʽʓʵɬʽʡȾႱࢠȟᄉႆȬɞȻպȾǾ
టൡ
NC
ͽʛʗʵɁ႕ᬂ˨Ⱦ͏˩Ɂɬʳ˂ʪʫʍʅ˂ʂȟ
᚜ᇉȨɟɑȬǿ
When a servo/spindle amplifier malfunction occurs, the
following messages appear on the NC operation panel.
• ‘EX0451
˿ᢉʓʳɮʠʰʕʍʒɬʳ˂ʪ
’
• ‘EX0451 SPINDLE DRIVE UNIT ALARM’
• ‘EX0457
˿ᢉʓʳɮʠʰʕʍʒɬʳ˂ʪ
#2’
• ‘EX0457 SPINDLE DRIVE UNIT ALARM #2’
5
ʇʟʒɷ˂
Ȍ
NC
ʁʃʐʪȍ
ɥઃȬҰȾɬʵʟɫʣʍʒɁ
“D”
ɥ
ઃȬȻǾɬʳ˂ʪႭհɥᆬᝓȺȠɑȬǿ
5
Press “D” before pressing
[NC SYSTEM]
soft-key to confirm the
alarm code.
ɬʳ˂ʪʫʍʅ˂ʂȟ᚜ᇉȨɟȲɜǾҤॅᄷюɁɿ˂ʦɬʽ
ʡᴬʃʞʽʓʵɬʽʡʰʕʍʒ˨
LED
ɥᆬᝓȪȹȢȳȨ
ȗǿ
When an alarm message is displayed, confirm the status of the
LEDs located above the servo/spindle amplifiers in the
electrical cabinet.
ᣮࢠɂ
LED
Ⱦɿ˂ʦɬʽʡᴬʃʞʽʓʵɬʽʡɁৰȟ᚜ᇉ
ȨɟɑȬȟǾႱࢠᄉႆɂɬʳ˂ʪᴬឬ֖Ⴍհȟ᚜ᇉȨɟɑ
ȬǿȲȳȪǾ
1
ᢉȕȲɝȾߦȪᛓୣɁɬʳ˂ʪȟպȾᄉႆ
ȪȲکնɂǾˢႭȪȗɬʳ˂ʪႭհɁɒɥ᚜ᇉȪɑȬǿ
In normal operation, the LEDs indicate the status of the servo/
spindle amplifiers. However, when a malfunction occurs, the
LEDs indicate alarm and warning codes. When more than one
malfunction occurs on a single axis, the LEDs indicate only the
latest alarm code.
8
ឬ֖
8
WARNING
1.
༧ɟȲਖ਼ȺʃɮʍʋɥͽȪȽȗȺȢȳȨȗǿɁՁى
ȾȽɝɑȬǿ
1.
Do not operate switches with wet hands otherwise you
could sustain an electric shock.
2.
᚜ᬂɵʚ˂ɥ۶ȪȲৰȺൡಽɥΈႊȪȽȗȺȢȳȨȗǿ
ᯚ٢ɁብފȝɛɆЭȟҋȪȹȗɞɁȺɁՁى
ȾȽɝɑȬǿ
2.
Do not operate the machine with the amplifier cover
removed. High-tension terminals and live parts are
exposed, and may cause electric shocks.
3.
ᣮ˹ȝɛɆᤆᢆ˹ɂ᚜ᬂɵʚ˂ɥᩒȤȽȗȺȢȳȨȗǿ
ɁՁىȾȽɝɑȬǿ
3.
Do not open the amplifier cover with the main power
turned ON otherwise you could sustain an electric
shock.
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......