INPUT/OUTPUT SIGNAL CONFIRMATION PROCEDURE
170
2
оҋӌαհɁᆬᝓศ
INPUT/OUTPUT SIGNAL CONFIRMATION PROCEDURE
టൡȾͷɜȞɁ᪩ȟᄉႆȪȲȻȠɂǾᜱႊ႕ᬂȺоҋӌ
ɁαհɥᆬᝓȪȹȢȳȨȗǿ
ՎᐎȻȪȹǾ˩ᜤȾటൡɁʁʃʐʪകᛵɥᇉȪɑȬǿ
When machine malfunctions occur, confirm the cause of the
problem by checking the status of input and output signals on
the diagnostic screen.
For reference purposes, a system outline for NL-series
machines is shown below.
5
PMC (Programmable Machine Controller) =
ʁ˂ɻʽɿᴷൡಽȻ
NC
ɁᩖɁαհɥ˹ፕȬɞЄȠɥȪɑȬǿ
5
PMC (Programmable Machine Controller) = Sequencer: relays
signals between machine and NC
ᴹαհɁ֞ᴻ
<Meaning of Signals>
ᴹᜱႊ႕ᬂɥ᚜ᇉȬɞศᴻ
<Diagnostic Screen Display Procedure>
ʳʊ˂َᬂɗَᬂȺᆬᝓȪȲȗоӌαհɁɬʓʶʃɥᝩ
ɌȲऻǾ͏˩Ɂਖ਼ᬲȺ႕ᬂ˨ɁαհɥʋɱʍɹȪǾȼȦȾץ
ᭉȟȕɞȞɥᜱȪɑȬǿ
Following confirmation of the input signal address to be
checked using ladder or electrical diagram displays, check the
signal status on the screen to locate the cause of the
malfunction.
Input Signal from Machine
Button
Limit Switch
Preparatory Control Signals
Output Signal to Machine
Lamp
Solenoid Valve
Relay
Commands to External Devices
Proximity Switch
ൡಽȞɜɁоӌαհ
ʦʉʽ
ᣋʃɮʍʋ
ʴʩʍʒʃɮʍʋ
ȰɁͅໄ϶ከျαհȽȼ
ൡಽɋɁҋӌαհ
ʳʽʡ
ʇʶʘɮʓʚʵʠ
ʴʶ˂
ȰɁͅ۶ൡبɋɁ͎Ƚȼ
αհ
Signal
ю߁
Item
X40 –
X5FF
ͽʛʗʵɗൡಽϫɁʴʩʍʒʃɮʍʋȞɜɁоӌα
հ
Input signals from operation panel or machine side limit
switches.
Y40 –
Y5FF
PMC
Ȟɜ᚜ᇉʛʗʵɗʇʶʘɮʓʚʵʠɋɁҋӌαհ
Output signals from PMC to display panel or solenoid
valve.
X600 –
X1FFF
PMC
Ȟɜ
NC
ɋɁҋӌαհ
Output signal from PMC to NC
Y600 –
Y1FFF
PMC
ɋɁ
NC
ȞɜɁоӌαհ
Input signal from NC to PMC
ൡᑤɷ˂
l
ᴥίަᴦ
D
Ȍ
NC
ʁʃʐʪȍ
D
Ȍ
I/F
ᜱȍ
D
ᜱႊ႕ᬂ
D
αհɬʓʶʃɥоӌ
D
\
ᴥоӌᴦ
ɷ˂
Function selection key
l
(SYSTEM)
D
[NC
SYSTEM]
D
[PLC-I/F]
D
Diagnostic Screen
D
Input signal
address
D
\
(INPUT)
key
Summary of Contents for NL1500/500
Page 8: ......
Page 9: ...CONTENTS FOR SAFE MACHINE OPERATION REGULAR MAINTENANCE TROUBLESHOOTING INDEX...
Page 10: ......
Page 19: ...FOR SAFE MACHINE OPERATION...
Page 50: ......
Page 51: ...1 1 CHAPTER 1 CHAPTER 1 REGULAR MAINTENANCE...
Page 167: ...2 2 CHAPTER 2 CHAPTER 2 TROUBLESHOOTING...
Page 181: ...181 ZERO POINT RETURN COMMAND ALARM TRIGGERED X X Axis Z Z Axis Y Y Axis...
Page 232: ......
Page 240: ......
Page 242: ......