background image

•  Only qualified personnel should assemble, 

install, operate or maintain this equipment.

•  Read all available documentation before 

assembly and operation.

•  It is vital to ensure that all system 

components are connected to earth ground.

•  This product contains electrostatically 

sensitive components that can be damaged 

by incorrect handling.

TXM

TXM34Q/C Quick Setup Guide

You will need these items to setup the TXM34Q/C:

•  A 24-70VDC power supply

•  A 12-48VDC auxiliary power supply (if needed)

•  A PC running Microsoft Windows XP, or Windows7/8/10 

with an RS-232 serial communication port, otherwise 

a USB to RS-232 serial port converter is needed. For 

CANopen drives, CANopen communication tool is 

required. For RS-485 drives, a USB to RS-485 converter 

is needed. For Ethernet drives refer to Section 3.2.5 

"Connecting to a PC using Ethernet" in the hardware 

manual for information on configuring the Ethernet on the 

PC and motor

•  Software: Step-Servo Quick Tuner

•  A power cable, I/O cable, and communication cable. 

Requirements:

Step 1

Install Software

a) 

Download the "Step-Servo Quick Tuner" from MOONS' website.

b) 

Install the "Step-Servo Quick Tuner" software application. 

c) 

Connect the motor to the PC using the programming cable. 

    (See "Communication Wiring" below)

d) 

Choose the correct COM port. 

    (See "Choosing the Right COM Port" below)

e) 

Run the software application. 

Step 2

Connect the Power Supply

Use power supply mating cable: Part number 1408835 from Phoenix Contact.

a) 

Connect the main power supply "+" terminal to the mating cable "BK1" terminal & the power supply "-" terminal to  

     the mating cable "BK2" terminal.

b) 

Optional - If the Keep Alive function will be used, connect the auxiliary power supply "+" terminal to the mating 

     cable "BK3" terminal & the power supply "-" terminal to the mating cable "BK2" terminal.  

Be careful not to reverse the wires. Reversing the connection may open the internal fuse and void the warranty

If a regulated power supply is being used, there may be a problem with regeneration that can be solved with the 

use of a MOONS' RC880 Regeneration Clamp. See MOONS' website or the TXM34Q/C Hardware Manual for more 

information.

NOTE:  For best performance, when using the optional auxiliary power supply, the main power must be applied prior 
to the auxiliary power.

RC880

TXM

V

-

V

+

BK3

Vin

+

-

to Earth

Ground

Main Power Supply

24-70VDC

12-48VDC

AUX Power Supply

V

+

V

-

BK2

BK1

Vout

+

-

(optional)

Safety Instructions:

These 3 cables are NOT included and must be 

purchased separately. For more detailed information, 

refer to the TXM34Q/C Hardware Manual, available at 

www.moonsindustries.com

5

1

2

3

1

2

BK (1)

3

PE

BK (2)

BK (3)

GN/YE

M12 plug pin assignment

Reviews: