MINV(arg)
Mode Inverse (Commutation Inverse)
APPLICATION:
Motion control
DESCRIPTION:
Inverts (reverses, negates, turns around) the direction con-
vention of the motor
EXECUTION:
Immediate
CONDITIONAL TO:
N/A
LIMITATIONS:
Do not apply while motor drive is enabled
READ/REPORT:
N/A
WRITE:
Write only
LANGUAGE ACCESS:
N/A
UNITS:
N/A
RANGE OF VALUES:
Input: 0 or 1
TYPICAL VALUES:
0
DEFAULT VALUE:
0
FIRMWARE VERSION:
5.x and later
COMBITRONIC:
MINV(0):3
where ":3" is the motor address — use the actual address or a
variable
DETAILED DESCRIPTION:
The MINV (Mode Inverse) command inverts the direction convention (orientation) of the
SmartMotor as follows:
l
MINV(0) restores the default direction convention
l
MINV(1) inverts the direction convention
When looking at the end of the motor shaft, the default direction convention of the
SmartMotor is clockwise shaft rotation = positive encoder counts, and counterclockwise shaft
rotation = negative encoder counts. Issuing the MINV(1) command inverts (flips) this
direction convention.