P
ar
t
2: C
omman
d
s
Moog Animatics SmartMotor™ Developer's Guide, Rev. L
Page 575 of 909
MFSLEW(distance[,m/s])
Mode Follow Slew
APPLICATION:
Motion control
DESCRIPTION:
Follow mode slew at ratio for a fixed distance
EXECUTION:
Buffered until a G command is issued, or a profiled move
restarts through MFSDC
CONDITIONAL TO:
MFR, MSR or MC modes
LIMITATIONS:
N/A
READ/REPORT:
N/A
WRITE:
Write only
LANGUAGE ACCESS:
N/A
UNITS:
Encoder counts from encoder input or internal counter (select-
able)
RANGE OF VALUES:
Input:
value: -1 to 2147483647
[m/s]: 0 or 1
TYPICAL VALUES:
Input:
value: -1 to 2147483647
[m/s]: 0 or 1
DEFAULT VALUE:
-1 (no ramp, follow mode immediately at ratio)
FIRMWARE VERSION:
5.x and later
COMBITRONIC:
MFSLEW(1000,1):3
where ":3" is the motor address — use the actual address or a
variable
DETAILED DESCRIPTION:
The MFSLEW command sets the follow mode slew at ratio for a fixed distance. It uses the
format:
MFSLEW(distance[,m/s])
where:
l
distance
Specifies counts — valid values from -1 to 2147483647. Set to -1 (default) to disable.
When disabled, Follow mode continuously runs at ratio. A distance of 0 is acceptable. It
produces a motion where only the MFA and MFD ramps form a triangular profile.
l
m/s
(Optional) Specifies the meaning of exp1. Values are: 0 for designating input units
(master units); 1 for designating distance traveled (slave units).
Part 2: Commands: MFSLEW(distance[,m/s])