Connection Manager Object (0x06)
Moog Animatics Class 6 EtherNet/IP Guide, Rev. B
Page 69 of 160
Connection Manager Object (0x06)
The following tables provide the Class and Identity Attributes, and the Supported Services for
the Connection Manager Object (0x06).
Class Attributes
Attrib
ID
Access
Rule
Name
Data
Type
Description
Semantics
1
Get
Revision
UINT
Revision of this object.
Default Value: 1
The current assigned
value is 1. If updates
require an increased
value, the value
increases by 1.
2
Get
Max Instance
UINT
Maximum instance
number of this object.
Default Value: 1
The largest instance
number of a created
object at this class hier-
archy level.
3
Get
Number of
Instances
UINT
Number of object
instances currently cre-
ated at this class level
of the device.
Default Value: 1
The number of object
instances at this class
hierarchy level.
6
Get
Maximum
ID Number Class
Attributes
UINT
The attribute ID num-
ber of the last class
attribute of the class
definition implemented
in the device.
7
Get
Maximum
ID Number
Instance Attrib-
utes
UINT
The attribute ID num-
ber of the last instance
attribute of the class
definition implemented
in the device.
Instance Attributes
None.
Services
Service
Code
Supported in:
Name
Description
Class Instance
0x0E
●
●
Get_Attribute_Single
Returns the contents of the specified
attribute
0x10
●
Set_Attribute_Single
Modifies an attribute value.
0x4E
●
Forward_Close
Closes a connection
0x54
●
Forward_Open
Opens a connection
For more details, see
THE CIP NETWORKS LIBRARY, Volume 1: Common Industrial Protocol
(CIP™)
, which is available on the ODVA.org website.