MSD Multi-Axis System Operation Manual DC-AC Servo Drive
moog
Id. no.: CA97554-001 0
5
/2017
87
A Technical data
A
Technical data
A.1 Current carrying capacity,
MSD Servo Drives DC-AC
The maximum permissible DC-AC Servo Drive output current and the peak current are
dependent on the DC supply voltage, the motor cable length, the power stage switching
frequency, the design of the cooling and the ambient temperature. If the conditions
change, the maximum permissible current carrying capacity of the DC-AC Servo Drives
also changes.
A.1.1
G393-004 to G393-032 (
air cooling, 400 V AC)
Device
Switching
fr
equency
of the
power stage
Ambient
temper
atur
e
Rated curr
ent
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-004 (Size 1)
4
+40
(+104)
5.3
8.4
8.4
10
11.9
0.5
8
4.0
8.4
8.4
-
-
12
3.7
6.6
6.6
-
-
16
2.7
5.2
5.2
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)
Table A.1 Rated and peak current, G393-004 to G393-032 (air cooling, 400 V AC)
Device
Switching
fr
equency
of the
power stage
Ambient
temper
atur
e
Rated curr
ent
Peak current
1)
I
MAX
0 Hz
I
1MAX
≥5 Hz
t
1
2)
I
2MAX
≥5 Hz
t
2
2)
[kHz]
[°C (°F)]
[A
eff
]
[A
eff
]
[A
eff
]
[s]
[A
eff
]
[s]
G393-006 (Size 1)
4
+40
(+104)
8.0
12.7
12.7
10
18.0
0.5
8
6.0
12.7
12.7
-
-
12
5.5
9.9
9.9
-
-
16
4.0
7.7
7.7
-
-
G393-008 (Size 2)
4
+40
(+104)
9.3
15.9
15.9
10
23.9
0.5
8
9.3
15.9
15.9
-
-
12
6.7
9.4
9.4
-
-
16
5.5
7.7
7.7
-
-
G393-012 (Size 2)
4
+40
(+104)
14.0
24.0
24.0
10
36.0
0.5
8
14.0
24.0
24.0
-
-
12
10.0
14.1
14.1
-
-
16
8.2
11.5
11.5
-
-
G393-016 (Size 3)
4
+40
(+104)
20.0
33.6
33.6
10
48.0
0.5
8
16.0
33.6
33.6
-
-
12
11.0
23.6
23.6
-
-
16
8.5
19.4
19.4
-
-
G393-020 (Size 3)
4
+40
(+104)
25.0
42.0
42.0
10
60.0
0.5
8
20.0
42.0
42.0
-
-
12
13.8
29.6
29.6
-
-
16
10.0
22.8
22.8
-
-
1) At maximum 70 % pre-load
2) Shutdown as per I²t characteristic
All data apply for a motor cable length ≤10 m (32.80 ft)