2-6.
PROFILE DATA LIST
Prpfile Data address and data
form
address
name
range
screen
content
1
File no
1
~
100
F3
"0" is F1 screen profile data
2
File name
F1,F2,F3,F5 max 32 characters
3
Date
F3
yy/mm/dd hh:mm:ss 17 characters
4
00
Shot size/Cycle
time
1
~
9999
F1
Shot size[0.1%]/Cycle time[0.1sec]
5
01
Die gap
0
~
1000
F1
[0.1%]
6
02
Delay
0
~
9999
F1
[0.1%]
7
03
Cushion
0
~
9999
F1
[0.1%]
8
04
Die gap slope
1
~
9999
F2
[0.1%/sec]
9
05
Start slope
1
~
9999
F2
[0.1%/sec]
10
06
Spline
0=invalid
SHIFT→F4
1=valid
11
07
Core stroke
1
~
9999
SHIFT→F1
unit
0.01mm
Tooling length
12
08
Accum. stroke
1
~
9999
SHIFT→F1
unit
0.1mm
13
09
DCDT zero
-1000
~
1000
SHIFT→F1
set voltage : unit [0.01V]
14
0A
DCDT span
-1000
~
1000
SHIFT→F1
set voltage : unit [0.01V]
15
0B
Accum. Empty
0
~
1000
SHIFT→F1
set voltage : unit [0.01V]
16
0C
Accum. Full
0
~
1000
SHIFT→F1
set voltage : unit [0.01V]
17
0D
Type set
bit0: 0 = Divergent, 1=
Convergent
SHIFT→F1
(
Core type)
bit1: 0 = %,
1 = mm
(
Core stroke unit
)
bit2: 0 = %,
1 = mm
(Accumulator stroke unit
)
bit3: 0 = Extrusion fixed, 1 =
Filling fixed
(
Accumulator type only
)
bit4: 0 = OFF, 1 = ON
(
Auto cycle
)
18
0E
Gain
1
~
32767
SHIFT→F1
[0.01]
19
70
Marker point 1
0
~
200
F2
Profile point 1
~
200
(
"0" is not out-
put
)
20
71
Marker point 2
0
~
200
F2
21
72
Marker point 3
0
~
200
F2
22
73
Marker point 4
0
~
200
F2
23
74
Marker point 5
0
~
200
F2
24
75
Marker point 6
0
~
200
F2
25
76
Marker point 7
0
~
200
F2
26
77
Marker point 8
0
~
200
F2
27
78
Marker point 9
0
~
200
F2
28
79
Marker point 10
0
~
200
F2
29
80
Profile point 1
-1
~
1000
F1
[0.1%]
30
81
Profile point 2
-1
~
1000
F1
[0.1%]
~
~
~
~
~
~
228
147
Profile point 200 -1
~
1000
F1
[0.1%]
229
148
PURGE gap
0
~
1000
[F2]
[0.1%]
230
149
TOOLING gap
0
~
1000
[F2]
[0.1%]