Page 1: ...inted dome replaces 2 x 2 ceiling tile with 2 Day Night cameras 3 9mm auto iris lens QODT4 70NA Drop Ceiling indoor housing tinted dome replaces 2 x 2 ceiling tile with 4 Day Night cameras 3 9mm auto iris lens Before attempting to connect or operate this product please read these instructions completely 81 IN5257 12 20 2011 2011 Moog Videolarm Inc All Rights Reserved ...

Page 2: ...n be damaged if improperly handled or dropped If an item appears to have been damaged in shipment replace it properly in its carton and notify the shipper Be sure to save 1 The shipping carton and packaging material They are the safest material in which to make future shipments of the equipment 2 These Installation and Operating Instructions If technical support or service is needed contact us at ...

Page 3: ...spect to any Product requiring service during the warranty period which is subjected to any of the following abuse improper use negligence accident lightning damage or other acts of God i e hurricanes earthquakes modification failure of the end user to follow the directions outlined in the product instructions failure of the end user to follow the maintenance procedures recommended by the Internat...

Page 4: ...per current needed for power supplies for Q View cameras Use Class 2 Power only Input voltage must be 24 VAC VDC WIRING 1 Make the proper connections to the incoming power The RED wire is POSITIVE the BLACK wire is NEGATIVE For reference purposes Polarity is not important in this unit The GREEN wire labeled Ground is GROUND for VAC or VDC connections NOTE Connect green ground wire to earth ground ...

Page 5: ... and 8 FACTORY DEFAULT FIXED AND FIXED VARI FOCAL LENSES Dip Switches 5 and 7 on all others off Figure 7 FACTORY DEFAULT AUTO IRIS LENSES Dip Switches 3 5 and 7 on all others off Figure 8 Figure 6 Hi Res Color Fixed and Vari focal fixed lenses Dip Switches Auto Iris adjustment screw DO NOT ADJUST Factory Use Only Connection to Power Board NOTE Dip switches are factory pre set for optimum performan...

Page 6: ...utter speed and gain using other switches See the tables below for specific settings MC CAMERA DIP SWITCH SETTINGS CHART SHUTTER SPEED Flickerless 1 BLC 2 MIRIS 3 Shutter Speed On Off Off 1 100 Sec Off On Off 1 60 Sec GAIN MIRIS 3 AEREF 9 AGCMAX 5 Gain On Off Off 0dB On On Off 6dB On Off On 12dB On On On 18dB Allows day night cameras to switch to b w in low light conditions also helps with low lig...

Page 7: ...istance 4 DO make sure the pair of wires carrying the video signal is sent as a twisted pair e g the blue white white blue wires twisted together as a pair not a split pair e g blue white conductor part of one pair orange white conductor part of another pair Wire What NOT to DO 1 Do not use shielded twisted pair wire It will severely degrade the distance performance Short runs may be used with som...

Page 8: ...3 ...

Page 9: ...LINES ON SCREEN PICTURE IS CLEAR LOW OR NO COLOR PICTURE IS DARK OR GRAINY IN GOOD LIGHTING CONDITIONS The auto iris lens is set at the factory If you experience video too light or dark you can manually adjust using the auto iris adjustment screw If there is low or no color the Auto Iris is too open if the picture is dark or grainy in good conditions the Auto Iris is too closed To adjust the auto ...

Page 10: ...k polarity WON T SYNC TORN PICTURE 1 Make sure that you are using unshielded twisted pair wire 2 Check distance equalization settings 3 For installations with passive non amplified transceivers at both ends check for ground loops This may be done with an AC Voltmeter as shown below If the voltage is greater than 1 2 volt use an amplified receiver such as the NV 652R NV 862R or NV 1662R Alternately...

Page 11: ...D POWER SUPPLY 24 AWG 22 AWG 18 AWG 16 AWG 1 2 5W 24 VAC VDC 1718 523 2733 833 6909 2106 10985 3348 2 5W 24 VAC VC 834 254 1327 404 3356 1023 5335 1626 3 7 9W 24 VAC VDC 529 161 842 256 2129 649 3385 1032 4 10 9W 24 VAC VDC 359 109 572 174 1447 441 2300 701 NOTE The above table is based on a worst case power supply Using a regulated or switching power supply can increase your cable distance Moog V...

Page 12: ...Housings Poles Power Supplies and Accessories and 5 Years on camera systems SView QView Warriors and InfraRed Illuminators Register Your ProductsOnline Take a few moments and validate your purchase via the Online Product Registration Form at www videolarm com productregistration jsp Register your recent Moog Videolarm purchases and benefit from the following Simple and Trouble Free RMA process Add...