11
Installation
XG0799 - 081319
In-Line Mounted
Power
vent
Positive
pressure
rated pipe
Power vent wire
Power supply
wire 208V,
15A
Control
Panel
Control
cable 9
wire
LED Power
120V, 2A
Wall
switch
B Vent
MODEL SIZE
3'
4'
5'
6'
7'
8'
’A’
7 7/8”
9 7/8”
9 7/8”
9 7/8”
9 7/8”
11 7/8”
Never install the Power Vent motor pointing up or down.
The Power Vent motor must always be installed in the horizontal
plane. Additionally the Power Vent must be securely mounted in a
manner which also allows the possibility for the access door to be
opened. The Motor/Access Door must have at least 12” of additional
clearance to be able to pull out the Motor/Access Door/Fan Wheel
assembly for servicing. -The structure which the Power Vent is
mounted to must be Non-Combustible Material Only.
CAUTION
B or C
Vent
B or C
Vent
85/8"
47/8"
171/16"
23716"
7"
91/16"
14"
117/8"
193/8"
A
1313/16"
11"
81/2"
16"
*NEVER INSTALL THE MOTOR WITH ITS SHAFT VERTICALLY, THE MOTOR
AXIS MUST BE HORIZONTAL
** ENSURE ACCESS DOOR CAN OPEN AT LEAST 80 DEGREES