19
Installation
XG0199 - 170223
Figure 10.
PL42DF*
Propane
Top Vent Venting Graph for wall mounted terminations.
Figure 10.b
PL42DF*
NG
Top Vent Venting Graph for wall mounted terminations.
Figure 10.c
Top Vented, wall mounted Multi-elbow installation. See Venting Graph for Top vent,
wall mounted terminations, Figure 10 or 10b.
Figure 10.d
Top Vented, wall mounted Multi-elbow installation. The vent run must comply with
Venting Graph for Top vent, wall mounted terminations, Figure 10 or 10.b
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 144", this would be an
acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 36" and the horizontal run
to the wall flange of the vent termination is 84", this would not be an
acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this
would not be an acceptable installation.
PROPANE VENT RUN
NATURAL GAS VENT RUN
Top Venting Graph P42, PL42:
Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar
to the wall flange of the termination. Plot on the Venting Graph Figure
10 or 10.b with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Heat
Shield
Termination
Hearth
Exterior
Wall
39" Min. (NG)
44" Max. (NG)
Flex section
63" Min. (LP)
16" Max. (LP)
Notes Wall Mounted Terminations: TOP VENT
• All measurements for vertical or horizontal runs are measured from
center of the vent pipe.
• Venting runs must fall within the limits set by the venting graph, see
Figure 10 or 10b.
0
HEARTH
12
12
0
60
36
84
120
24
72
108
48
96
132
Vertical Height (In.)
Horizontal Run (In.)
36
60
84
108
132
156
24
48
72
96
120
144
168 180
0
HEARTH
12
12
0
60
36
84
120
24
72
108
48
96
132
Vertical Height (In.)
Horizontal Run (In.)
36
60
84
108
132
156
24
48
72
96
120
144
168 180
Acceptable vent run
within non-shaded area.
Acceptable vent run
within non-shaded area.
Unacceptable vent run
within non-shaded area.
Unacceptable vent run
within shaded area.
A
A
B
B
C
C
Heat Shield
Flex section
Hearth
Termination
Exterior
Wall
40 1/2" Min. (NG)
53" Min. (Propane)
44" Max. for minimum vertical (NG)
12" Max. for minimum
vertical (Propane)
Flex Section
Hearth
30”min
15’Max.
Heat
Shield
Termination
Exterior
Wall
9’ Min at Max.
Horizontal
(NG)
10’ Min at Max.
Horizontal
(LP)
15' Max.
for minimum
vertical
30" Min.
Heat
Shield
Termination
Flex section
Solid section
Hearth
9’ Min at Max.
Horizontal (NG)
10’ Min at Max.
Horizontal (Propane)
Exterior
Wall
53''
12''
40½''
44''