17
Installation
XG0199 - 170223
Figure 8.
PL38DF* Propane Top Vent Venting Graph for wall mounted terminations.
Figure 8.b
PL38DF* NG Top Vent Venting Graph for wall mounted terminations.
Figure 8.c
Top Vented, wall mounted Multi-elbow installation. See Venting Graph for Top vent,
wall mounted terminations, Figure 8 or 8.b
Selection of components and details of venting layout should adhere
to the following guidelines:
• Vent terminations must not be recessed in walls or siding.
• For Heat Shield requirements see Section 3-3 on page 14.
• Once the proposed venting layout has been determined refer to
Figure 8, 8b, 8c to ensure the layout is acceptable.
Notes Wall Mounted Terminations: TOP VENT
• All measurements for vertical or horizontal runs are measured from
center of the vent pipe.
• Venting runs must fall within the limits set by the venting graph,
see Figure 8 or 8b.
Example A: (Acceptable Installation)
If the vertical dimension from the hearth is 120" and the horizontal
run to the wall flange of the vent termination is 144", this would be an
acceptable installation.
Example B: (Unacceptable Installation)
If the vertical dimension from the hearth is 36" and the horizontal run
to the wall flange of the vent termination is 84", this would not be an
acceptable installation.
Example C: (Unacceptable Installation)
If the vertical dimension from the floor of the fireplace is 60" and the
horizontal run to the wall flange of the vent termination is 144", this
would not be an acceptable installation.
Top Venting Graph P38, PL38:
Measure the vertical height from the fireplace hearth to the centre of
the termination and the horizontal run from the fireplace flue collar
to the wall flange of the termination. Plot on the Venting Graph Figure
8 or 8b with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the
installation is acceptable.
Wall mounted Terminations:
The following details are some possible configurations for Wall mounted
terminations. See below.
Heat
Shield
Termination
Hearth
Exterior
Wall
39" Min. (NG)
44" Max. (NG)
Flex section
63" Min. (LP)
16" Max. (LP)
NATURAL GAS VENT RUN
PROPANE GAS VENT RUN
0
HEARTH
12
12
0
60
36
84
120
24
72
108
48
96
132
Vertical Height (In.)
Horizontal Run (In.)
36
60
84
108
132
156
24
48
72
96
120
144
168 180
0
HEARTH
12
12
0
60
36
84
120
24
72
108
48
96
132
Vertical Height (In.)
Horizontal Run (In.)
36
60
84
108
132
156
24
48
72
96
120
144
168 180
Acceptable vent run
within non-shaded area.
Acceptable vent run
within non-shaded area.
Unacceptable vent run
within shaded area.
Unacceptable vent run
within shaded area.
A
A
B
B
C
C
Section 3-3-1: Venting Layout: Wall Mounted Termination
Heat Shield
Flex section
Hearth
Termination
Exterior
Wall
39" Min. (NG)
63" Min. (Propane)
44" Max. for minimum vertical (NG)
16" Max. for minimum
vertical (Propane)
63''
16''
39''
44''
Summary of Contents for P38
Page 51: ...51 Notes XG0199 170223 ...