11
Installation
XG0199 - 170223
Clearances:
Installing The Standoffs
MODEL
Top - Rear
vent
†
Top - Top
vent
†
Rear
Sides
Floor††
Mantel
Vent Pipe
P38DF*
PL38DF*
9"
17 1/2"
0"
0"
0"
See Section 6
Finishing around the
fireplace
1'' all around
2" on the
horizontal
P42DF*
PL42DF*
9"
17 1/2"
0"
0"
0"
See Section 6
Finishing around the
fireplace
1'' all around
2" on the
horizontal
P52DF*
PL52DF*
12"
26"
1"
2 1/2"
†††
0"
See Section 6
Finishing around the
fireplace
1'' all around
2" on the
horizontal
NOTES:
†
Clearance from top of fireplace to a ceiling within the fireplace
enclosure.
†† Four sided surrounds require a raised installation.
††† 2 1/2" clearance is from the main body of the firebox, NOT the
insulated flange. Clearance to the insulated flange is 1".
Figure 4.
Combustible Wall Clearances
P38, PL38, P42, PL42:
When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
For Rear Vent applications, the minimum clearance is 0" from the rear
of the fireplace to a wall, or any combustible materials, and 9" clearance
from the top of the fireplace to the underside of any combustible shelf
materials.
For Top Vent applications, the minimum clearance is 0" from the rear
of the fireplace to a wall, or any combustible materials, and 17 1/2" to
the underside of any combustible shelf materials.
To avoid elevated mantel temperatures, all P and PL gas fireplaces
are required to have the supplied standoffs installed. The fireplace is
supplied with two standoffs. Bend and install these standoffs on top
of the fireplace ensuring that the height of the standoff maintains a
7 1/2" clearance.
P52, PL52:
When installing a shelf over the top of the fireplaces, the following
guidelines must be adhered to:
For Rear Vent multi-elbow applications, the minimum clearance is 1"
from the elbow off the rear of the fireplace to a wall, or any combustible
materials, and 12" clearance from the top of the fireplace to the
underside of any combustible shelf materials.
For Top Vent applications, the minimum clearance is 1" from the rear
of the fireplace to a wall, or any combustible materials, and 26" to the
underside of any combustible shelf materials.
7½”
Figure 4.b Installing standoffs
The supplied nailing extension must be placed along the top edge of the
fireplace and securely fastened into place, as shown in
figure 4.c
. Note:
The nailing flange extension can be substituted with a piece of
NON-
Combustible
material of the same size and thermal characteristics, ie:
cement board or equivalent.
4"
Installing the Nailing Flange Extension
Figure 4.c
Bottom of Nailing Flange Extension
Figure 4.d
Bottom of Nailing Flange Extension with tab folded at 90 degree angle
Figure 4.e Insert folded tabs into slots above the front of the fireplace
Figure 4.f
Securing the Nailing Flange Extension.
Before installing the supplied nailing flange extension, fold tabs at
bottom of nailing flange to a 90 degree angle.
NOTE:
Do not install
nailing flange when installing a Montigo Surround.
Front of Nailing Flange
Front of Fireplace
Do not install nailing flange when installing a Montigo surround, use
equivalent non-combustible.
NOTICE