background image

XG0221

Installation & Maintenance Manual

•  The installation of this fireplace must be done by a 

qualified and certified gas appliance installer.

•  Check local codes and read all instructions prior to 

installation.

®

C

US

       WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, 

death, or property damage.

— Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

  Do not try to light any appliance.

  Do not touch any electrical switch; do not use any 

phone in your building.

•  Leave the building immediately.
•  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a qualified 

installer, service agency or the gas fitter.

Distinction

 INDOOR GAS FIREPLACE 

 

DL6315, DL6315ST, 

40,000 BTU/hr Natural Gas or Propane Gas

D6315, D6315ST

50,000 BTU/hr Natural Gas or Propane Gas

Installer:

 Leave this manual with the appliance. 

Consumer:

 Retain this manual for future reference. 

NOTICE

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing

Installation and service must be performed by a qualified installer, 

service agency or the gas fitter.

Summary of Contents for D6315

Page 1: ...the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation...

Page 2: ...tallation Information See Appendix B The Montigo warranty will be voided by and Montigo disclaims any responsibility for the following actions Modification of the fireplace and or components including...

Page 3: ...L I 2 Wiring Diagram 29 Installation of Electrical Supply 29 DL6315 ST N L I Wiring Diagram 30 Installation of the wall switch 30 CPI Continuous Pilot Ignition IPI Jumper Cable Installation 31 Why use...

Page 4: ...cal installations must conform to the local codes or in the absence of local codes to the current version of Canadian Electrical Code CSA C22 1 1 Installations in the USA must conform to the local cod...

Page 5: ...clearance Firestops installed Exteriorwall roofflashinginstalledandsealedincompliancewithlocalbuildingcode Terminations installed and sealed in compliance with local building code Direct vent terminat...

Page 6: ...XG0221 6 General Rating Plate Sample LBA120x Distinction Series no CSA 27 02 2017 Figure 1 Rating Plate for D6315 LBA120x Distinction Series no CSA 27 02 2017 Figure 1 b Rating Plate for DL6315...

Page 7: ...5 15 16 420 16 9 16 843 33 3 16 414 16 5 16 153 6 276 10 7 8 REVISIONS REV DESCRIPTION DATE CHANGED BY 1 32 DWG NO SHEET 2 OF 2 WEIGHT DL63 Full Assembly 16 Finish MATERIAL DIMENSIONS ARE IN INCHES TO...

Page 8: ...roducts Residential Products R D Projects DL63ST Cad Drawings DL63ST Full Assembly June 20 17 12 12 23 PM SCALE DM Description DL63ST Full Assembly Revision 410 16 1 8 1666 65 9 16 1628 64 1 8 403 15...

Page 9: ...MODEL Top Sides Floor Back Note Clearance from top of fireplace to a combustible ceiling within the fireplace enclosure Unprotectedcombustiblewallswhichareperpendiculartothefireplace opening must main...

Page 10: ...4 plywood platform 24 platform height requires a minimum of 8 ceiling height The unit can be placed on a 48 platform if a minimum of 10 ceiling is attained Determine the height of the platform based o...

Page 11: ...STRUCTURE PLATFORM REVISIONS REV DESCRIPTION DATE CHANGED BY 1 32 DWG NO SHEET 2 OF 2 WEIGHT DL63 Framing Assembly Finish MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES FRACTIONAL 1 16 TWO PLACE DECIMAL...

Page 12: ...nd provide a gas service shut off valve according to local gas codes Before fastening in place line up the front face of the fireplace Then secure in place with 1 4 lag bolts to the platform Place the...

Page 13: ...PRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED PROPRIETARY AND CONFIDENTIAL Y Products Residential Products R D Projects DL63 Cad Drawings D...

Page 14: ...e 8 b Framing Box Assembly See Through Mesurement is a 2x4 on side and a 3 4 plywood platform Mesurement is a 2x4 on side and a 3 4 plywood platform D6315ST A 18 7 16 B 89 C 79 D 50 E 72 F 18 7 16 G 5...

Page 15: ...ming SHEET SIZE CF 26 05 2017 CF 1 19 2017 Y Products Residential Products R D Projects DL63 Cad Drawings Manual Y Products Residential Products R D Projects DL63 Cad Drawings Distinction SHow Unit TV...

Page 16: ...g Venting Included Restrictor plates 1 Baffle 1 5 Baffle 1 75 Baffle The distinction is supplied with 3 different sized restrictor plates to improve flame efficiency The size of restrictor used largel...

Page 17: ...to measure the glass temperatureafter1hourofrunning andensuretheglasstemperature does not exceed 470 F and ensure that none of the media and no part of the door has discoloured Minimum 24 from top of...

Page 18: ...15ST DL6315ST Vertical Minimum V1 Horizontal Maximum H1 2 FT 3 FT 3 FT 6 FT 4 FT 9 FT 5 FT 12 FT 6 FT 15 FT 7 FT 18 FT 8 FT 21 FT D6315 DL6315 Vertical Minimum V1 V2 Horizontal Maximum H1 H2 2 FT 1 FT...

Page 19: ...H1 H2 D6315ST DL6315ST Vertical Minimum V1 Horizontal Maximum H1 H2 2 FT 3 FT 3 FT 6 FT 4 FT 9 FT 5 FT 12 FT 6 FT 15 FT 7 FT 18 FT 8 FT 21 FT D6315 DL6315 Vertical Minimum V1 Horizontal Maximum H1 H2...

Page 20: ...H2 D6315ST DL6315ST Vertical Minimum V1 V2 Horizontal Maximum H1 H2 2 FT 3 FT 3 FT 6 FT 4 FT 9 FT 5 FT 12 FT 6 FT 15 FT 7 FT 18 FT 8 FT 21 FT D6315 DL6315 Vertical Minimum V1 V2 Horizontal Maximum H1...

Page 21: ...ationlocationmustbeaminimum6 fromamechanicalairinlet A maximum of three offsets each offset is made up of 2 90 bends may be made for vertical vent runs Firestops must be installed as required by Natio...

Page 22: ...ed wall construction using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here from the inside and attach to the MOSR by installing a min quantity of 4 bolts into the thre...

Page 23: ...rity of internal supports For flex venting place the springs supplied with the pipe kit between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots Montigo recommends...

Page 24: ...PXT12 12 f f PXT20 20 f f 58DVA 08A 12 58DVA 16A 20 Rigid Telescopic Pipe 58DVA 17TA 58DVA 24TA E Elbows 5 8 Vent PEL 90MM m m 90 PEL 90FF f f 90 PEL 90FM f m 90 PEL 45FM f m 45 58DVA E30 30 58DVA E45...

Page 25: ...f m 45 5DE45 45 5DE90 90 Support Ring Plate PSPXT 8 5CS Firestop FS 8 5CS Heat Shield RHS101 5WT 5WTE Attic Radiation Shield 5AS 5RDS Wall Support 5WS Offset Support 5OS Vaulted Ceiling Support 5SS St...

Page 26: ...cture Figure 11 RHS102 Installation Install by sliding over vent pipe where it passes through the combustible construction Figure 11 b RHS101 Installation Install by sliding Outer Section over vent pi...

Page 27: ...d from the firebox 4 Loosen the 4 screws securing the burner strip to the stands 5 Carefully slide out burner strip from the firebox 6 Unscrew brackets securing metal plate to the bottom of the firebo...

Page 28: ...sion instructions 5 Use screwdriver to carefully detach spring clip from the pilot hood Spring clip will be reused 4 Use 3 8 Socket Driver to loosen off the NG gas orifice replace with Propane orifice...

Page 29: ...de of rating plate Attach Rating plate conversion label to rating plate label Place Valve conversion label on valve face 8 The pilot size can be adjusted using a flathead screwdriver to adjust pilADJ...

Page 30: ...10 6 OPTIONAL CPI IPI SWITCH WHITE LED Lights LED1 Red LED LED2 Amber LED SW1 LED o tro e r LED power s pp y white white white BLACK WHITE VARIABLE SPEED COMFORT FANS GAS ELECTRICAL ACCESS 414 16 5 16...

Page 31: ...with CSA C22 1 Canadian Electrical Code Part 1 and or Local Codes Installations in the USA must be electrically grounded in accordance with local codes or in the absence of local codes with the Nation...

Page 32: ...the pilot is partially recovered asheatintothebuilding soitdoesnotwasteasmuchenergyasrunning a pilot in the off season A connector is supplied with this unit that can be plugged into the wire harness...

Page 33: ...5 W C 0 45 PSIG 13 8 W C 0 5 PSIG Section 5 Installing the gas line After gas line is connected each appliance connection valve and valve train MUST be checked while under normal operating pressure w...

Page 34: ...nstalled with 6 clearance to the side of the fireplace as shown Mantels Surrounds with Cool Wall Kit Rear Standoff2 Side Standoff 3 1 3 Top Standoff 38 25 Combustible Mantle Height 24 Combustible Mant...

Page 35: ...reen Pull the bottom of the screen outward then slide out the screen from the frame Store in a safe place The Screen is very fragile and can be easily torn dented or deformed Refer to Figure 20 b belo...

Page 36: ...Distinction doors are removed in a few simple steps Follow these steps belowto unlatchthe door buckles and remove the door Replace in reverse order Hand hold Door Latch Slot Door Removal Tool Reinsta...

Page 37: ...ional speckled stones The unit has the option of installing the Speckled Stone These may be spaced at random or in a visual pattern of your preference See the Montigo web site for photographs and idea...

Page 38: ...TEP 1 Place log E from the LGS59 kit to the left of the pilot in the rear left corner of the unit STEP 4 Place log D parallel to log 4 at the front edge of the burner tray STEP 2 Place log A resting o...

Page 39: ...STEP 8 Place log 5 at the front of the burner tray STEP 10 Place log number 3 diagonally in the rear right corner of the firebox STEP 9 Log 6 is placed leaning on log 5 near the front of the firebox...

Page 40: ...E GREEN Lights ON OFF CONTROL MAIN Power 120VAC 60 Hz 6 Amps SPARK SENSOR RED BLACK BATTERY PACK MAIN ON OFF SWITCH YELLOW GREEN PILOT R ORANGE GREEN BLACK BROWN YELLOW ORANGE 6 10 6 OPTIONAL CPI IPI...

Page 41: ...place instructions 10 Loop Pilot wires from behind control board drawer to the front Plug into X2 and X3 8 Place Fan wire on leftside firebox floor with adhesive wire pad For fan Install instructions...

Page 42: ...ve the door please see the door install removal section For instructions on how to remove the burner tray please see the burner tray section 4 Place Glass plate where metal plate sat before secure usi...

Page 43: ...s are included The model number may be found on the rating plate under the valve blind of the fireplace See through installations receive the following reflective glass kit Only follow steps 1 2 and 5...

Page 44: ...Installation Step5 Oncethebackpanelsaresecure the2sidepanelscanbeinstalled Step 4 Repeat step 3 for middle and left panels Push panels together to prevent gaps Figure 26 d Secure panel Figure 26 e Sec...

Page 45: ...screws into the valve body Use a standard screwdriver or T20 Torx bit and tighten to the screws with a fixing torque of 251b in 5 IN THE EVENT THAT THE THREADS OF THE VALVE ARE STRIPPED OR DAMAGED RE...

Page 46: ...Connect control board connector located fastened on the bottom leftside of the firebox to fan harness 6 Connect fans to harness connectors tuck wires away from LED strip To Fan To Control Box To Fan T...

Page 47: ...ed Diagnostic Light LED2 Amber Programing Remote Control Light Power 3 15A Fuse Stepper Motor Main Harness Main ON OFF Switch Sensor Igniter Manifold Pressure Test Connection Pilot Adjustment Screw In...

Page 48: ...oducts Residential Products R D Projects DL63 Cad Drawings DL63 Framing Assembly December 12 16 12 44 38 PM SCALE DM Description Framing Assembly 3 A Revision DIMENSIONS ARE IN INCHES TOLERANCES FRACT...

Page 49: ...he features and a Thermostat Key is used to turn On Off or index through Thermostat functions see Figure 26 Additionally a Key Lock feature is provided The Proflame 2 System consists of the following...

Page 50: ...creen on the Remote Control to verify that a C or F is visible to the right of the Room Temperature display Turn On the Fireplace With the system Off turn the master override switch to on and press th...

Page 51: ...will change to show that the room thermostat is On and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed...

Page 52: ...lly take out one battery see Figure 26k 2 Insert the battery while holding down the thermostat button The remote screen will display Clr while the button is held down See Figure 26l 3 To enable thermo...

Page 53: ...17 Blue color glitters Adjustable Adjustable 18 Yellow color frequently blinks Adjustable Adjustable 19 Yellow color glitters Adjustable Adjustable 20 Circulation mode Item Parameters Working Voltage...

Page 54: ...g the initial firing Silicone seals will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed using normal household products Use a vacuum clean...

Page 55: ...ion air inlet to other appliance for appliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved dr...

Page 56: ...ted to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce ex...

Page 57: ...ign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Appendix C Amendment Gas Fireplace Equipment sold in the State of Massachuset...

Page 58: ...XG0221 Installation Maintenance Manual D6315 DL6315 Vented gas fireplace heater...