Remove the 3 screws on the switch

housing cover and save.

26

Install the switch housing cover by

aligning the 2 screws with the 2 key

slot holes on the plate and twist to

lock into place. Install the 1 screw re-

moved and tighten the other 2

screws securely.

25

Loosen 2 screws and remove 1 screw

and save.

24

Attach blade assembly to motor using

the motor screws and washers pro-

vided. Tighten screws securely.

23

Install 3 screws and washers per blade

and tighten securely.  Repeat for all 5

blades. (Blades sold separately)

Note:

This fan includes 2 sets of 18 blade

screws in 2 different lengths depending

on the thickness of the blade selected for

use with this fan.  Please select the length

that best fits the blade thickness.

22

Make wiring connections as indicated

above.  Connect black and blue wire from

fan to Black or (Hot) wire from house.

Connect White wire from Fan to White

(Neutral) wire from house.  Connect

Ground leads from mounting bracket and

downrod to Ground lead from house.

Refer to Safety Tips section of manual.

20

Make wire connections to power source using

wire nuts provided.  Make sure that no filiments

are outside of the wirenut. After making the

wire connections, the wires should be spread

apart with the grounded conductor and the

equipment-grounding conductor on one side of

the outlet box and ungrounded conductor on the

other side of the outlet box.

19

Loosen one and remove one preassem-

bled screw from mounting bracket. Save

screw. Lift canopy up, aligning its keyhole

slot with the preassembled screw on

mounting bracket and twist clockwise to

lock in place. Re-install the removed

screw and tighten all screws securely. 

21

For Canadian installation and for USA fan and

light kit combinations over 35 lbs, in both flush

and downrod modes the safety cable must be

installed into the house structure beams using

3” lag screws, washers and lock washers pro-

vided. Make sure that when the safety cable is

fully extended the lead wires are longer than

the cable and no stress is placed on the lead

ires.

Note

: If installing it in the U.S., Do Not Remove

Knockouts In The Outlet Box.

18

Safety cable installation

Safety Cable

Lag Screw

safety

cable

3” lag

screw

lock

washer

washer

Summary of Contents for AC-572LF2000

Page 1: ...R ADDRESS To register your fixture please visit our website www montecarlofans com 5RYXX Series Fan Total fan weight UL Model No AC 572LF2000 14 95 kgs 32 89 lbs ENERGY STAR approved with blades MC5B241 MC5B242 MC5B243 MC5B244 MC5B245 MC5B246 MC5B247 MC5B248 MC5B249 MC5B250 MC5B251 MC5B252 MC5B253 MC5B254 MC5B255 MC5B256 MC5B257 MC5B258 MC5B259 MC5B260 MC5B261 ...

Page 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Page 3: ...t of of 31 8kg 70 lbs or less Most outlet boxes com monly used for the support of lumminaires may not be acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 2 Remove the keeper pin and cross pin 9 Lift mounting neck to mounting Plate and align screws 7 Secure mounting neck to the mounting plate with 6 screws to become a complete mounting bracket 8 Sec...

Page 4: ... in motion Helpful Hint It will help to slip downrod ball into mounting bracket by slant ing fan assembly and canopy 12 Place canopy and then yoke cover over downrod Then thread the lead wires and safety cable from fan through the downrod as shown 11 13 Tighten both yoke set screws evenly to secure downrod Loosen the 2 set screws You should be able to put your downrod into the yoke 10 Remove the s...

Page 5: ...from house Refer to Safety Tips section of manual 20 Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box 19 Lo...

Page 6: ...ed double sided foam tap as shown 28 Align the reverse switch preassembled on switch housing with the long slot on switch housing cover as shown and then install the switch housing using the 3 screws previously removed Set ting the reverse switch in the left hand side will result in downward airflow and setting the switch in the right hand side will result in upward airflow Hook 29 ...

Page 7: ...N LQ SHULRG RI KRXUV 0RVW QRLVHV DVVRFLDWHG ZLWK D QHZ IDQ ZLOO GLVDSSHDU DIWHU WKLV SHULRG I WKLV LV D GRZQURG PRXQW IDQ PDNH VXUH WKH ULGJH RQ PRXQWLQJ EUDFNHW HQJDJHV WKH QRWFK LQ WKH GRZQURG EDOO 0DNH VXUH WKDW FDQRS PRXQWLQJ EUDFNHW RU PRXQWLQJ SODWH DUH WLJKWHQHG VHFXUHO WR FHLOLQJ MXQFWLRQ ER DQG MXQFWLRQ ER LV PRXQWHG UPO WR FHLOLQJ MRLVW KHFN WKDW DOO EODGHV DUH VFUHZHG UPO LQWR EODGH KRO...

Page 8: ...Feb 2012 New format Jul 2013 Update for CUL regulation ...

Reviews: