background image

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70-

1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on

one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being

switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag,

to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from

the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning.  Do not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip-

ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American

Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched

on accidentally.  When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the

service panel.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

Installation

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

S

AFETY

T

IPS

TOOLS REQUIRED

Phillips Screwdriver      Wire Cutters       Pliers      Step Ladder

Before you begin installing the fan, Switch power off

at Service panel and lock service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such  as a tag, to the service panel.

1

Before installing this fan make sure the outlet

box is properly installed to the house structure.

To reduce the risk of fire, electric shock, or per-

sonal injury, mount to outlet box or supporting

system acceptable for fan support. 

(Mounting must support at least 35 lbs.)

2

Use metal outlet box suitable for fan support

(must support 35 lbs). Before attaching fan to

outlet box, ensure the outlet box is securley

fastened by at least two points to a structural

ceiling member ( a loose box will cause the fan

to wobble). Install the mounting bracket with

the 2 screws provided with the outlet box.

Use only the screws provided with the out-

let box.  

3

Loosen the 2 set screws in yoke

for downrod to slip into yoke.

4

Remove the cotter pin and cross pin

from downrod. Replace cotter pin

into cross pin and save for steps

8 and 9.

5

Thread canopy and yoke cover on down-

rod. Thread leadwires through the down-

rod.

Follow inserts as shown above.

6

Canopy

Yoke cover

Downrod  

Ball

Summary of Contents for 5SRR54XXD Series

Page 1: ...Owner s Manual Ceiling Fan Installation Instructions READ AND SAVE THESE INSTRUCTIONS Total fan weight with lights 5SRR54XXD Series Fans ...

Page 2: ...eded for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch pow...

Page 3: ...e units will communicate properly If you have other fans you can set to control from one trans mitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different posi tions to have seperate control 14 Remote Transmitter Dip switches Remote Receiver Dip switches Install remote receiver by sliding into opening in the Mount...

Page 4: ... 2 screws Save screw 21 Align keyslot holes of the light kit plate and twist to lock Add the screw removed from step 21 Tighten securely 24 25 28 Install 3x40 watt candelabra bulbs Bulbs are not included Install the hex nut to the glass to secure in place Install the decorative finial nut to secure the glass in place 29 Attach the glass to the light fixture 26 Connect white wire from fan to white ...

Page 5: ... in place Place face plate over battery compartment and buttons Place remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snapping into place Install wall control unit to outlet box using machine screws provided 33 32 31 HAND HELD INSTALL WALL MOUNT INSTALL Attach front cover to wall control with screws provided Snap battery cover in place 34 ...

Page 6: ...immer once quickly To turn off press once quickly while light is on To dim light hold down button light dimmer The light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only LIGHT ON OFF SET TING AND DIMMER Press and hold to dim light infinitively LED LIGHT ...

Page 7: ...ed between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly resu...

Reviews: