background image

© 2011 Monte Carlo Fan Company

5/10/2012

2

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA
70-1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer.  If you have  any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor
on one side of the outlet box and ungrounded conductor on the other side of the outlet box. The splices, after being made, should be
turned upward and pushed carefully up into the outlet box.

WARNING

: Before you begin installing the fan, servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.

Be cautious! Read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet
from the floor to the trailing edge of the blade.

WARNING

: To Reduce The Risk Of Fire, Electric Shock, or Personal Injury, Mount To Outlet Box Marked “Acceptable for Fan Support of

31.8 kg (70 lbs) or less” And Use Mounting Screws Provided With The Outlet Box.

CAUTION: 

For Compliance with Local Codes and Regulations, If Installing The Secondary Support Safety Cable in the U.S., Do Not Re-

move Knockouts In The Outlet Box. Mount the secondary support safety cable through the reserved nail/screw hole on the outlet box to
the building structure (or the ceiling joist).

WARNING

: To reduce the risk of personal injury, do not bend blade holders during installation to motor, balancing or during cleaning.  Do

not insert foreign object between rotating blades.

Attach the mounting bracket using only the hardware supplied with the outlet box.

WARNING

: To reduce the risk of fire or electric shock, this fan must be installed with an isolating wall control/switch.

WARNING: 

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed

control.

If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

Never place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating
equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

CAUTION

: To Reduce the Risk of Electric Shock, Disconnect the electrical supply circuit to the fan before installing the light kit. 

All set screws must be checked and tightened where necessary before installation. 

Customer Service

800-969-3347

Customer Service Center

7400 Linder Ave.

Skokie, IL 60077

www.montecarlofans.com

Tools Required for Assembly (not included): Electrical Tape, Phillips Screwdriver, Pliers, Safety Glasses,

Stepladder and Wire Strippers.

Summary of Contents for 5SBR56XXD-L Series

Page 1: ...rd and retain as your proof of purchase DATE OF PURCHASE MODEL NUMBER RETAILER NAME RETAILER ADDRESS To register your fixture please visit our website www montecarlofans com 5SBR56XXD L Series Fan Total fan weight with light kit UL Model No AC 556LF4000 18 5 kgs 40 7 lbs ...

Page 2: ... Use Mounting Screws Provided With The Outlet Box CAUTION For Compliance with Local Codes and Regulations If Installing The Secondary Support Safety Cable in the U S Do Not Re move Knockouts In The Outlet Box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of personal injury do...

Page 3: ...ety bar from mounting bracket by loosing screws sliding bar to side and lifting it off the 2 screws 3 Remove the 6 screws attaching the Mounting neck the mounting plate Retain the 6 screws for re assembly 4 Loosen 2 screws and remove gate Save gate for use later 9 Lift mounting neck to mounting Plate and align screws 7 Secure mounting neck to the mount ing plate with 6 screws to become a complete ...

Page 4: ...an not feel screws on inside of yoke 10 15 12 13 Use 3 screws removed to attach arch brackets to arch hub 11 14 Slide canopy ball arch assembly and yoke cover over downrod Thread lead wires and safety cable through downrod as shown Remove keeper from cross pin and then cross pin from yoke Replace keeper on cross pin and save Align hole in downrod with hole in yoke and install cross pin Install dow...

Page 5: ... Install remote receiver by sliding into opening in the Mounting bracket Make sure that the dip switches on the Transmitter and the Receiver are set to the same position See Fig 39 for remote operation 22 white black Make wiring connections as indicated above White from fan to white from remote marked N Orange from fan to Orange from remote marked Light up Blue from fan to blue from remote marked ...

Page 6: ... breaker or by remote Replace bulbs with the correct wattage bulbs turn the power on Lift light kit to the fan motor assembly Align the 3 screws with the key hole slot holes in the light kit see inset Rotate the light kit as shown Then install the screw removed in the previous step though the closed hole Tighten all 3 screws securely 32 33 Twist light kit into place by turning direction of arrow 3...

Page 7: ... remote over 2 pins on front cover Attach cover of remote by placing over 4 pins and snaping into place 37 HAND HELD INSTALL Install wall control unit to outlet box using machine screws provided 38 Attach front cover to wall control with screws provided Snap battery cover in place 39 WALL MOUNT INSTALL ...

Page 8: ...light will cycle from bright to dim to bright until button is released Light will maintain last setting if turned off FORWARD REVERSE Depress rev button allow a few seconds for remote to change rotation direction with fan running HIGH SPEED MEDIUM SPEED LOW SPEED FAN OFF SETTING Turns fan off only FAN REVERSE Press once to change direction of the fan Fan must be running to reverse UPLIGHT ON OFF S...

Page 9: ... following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two ...

Page 10: ...REV 1 2 4 04 Step 8 in safety tips step 2 page 2 battery remote ...

Reviews: