12

Slip downrod into motor housing yoke, 

aligning holes and install cross pin and 

keeper pin. 

Insert cross pin through yoke and downrod 

until point appears on the other side, and 

insert keeper pin on cross pin. 

Pull the downrod up tight against the 

cross pin, and then evenly tighten the 

downrod set screws on motor housing 

yoke. 

Place yoke cover on top housing of fan.

Warning

: Cross pin and keeper pin must 

be installed securely, failure to install them 

will result in serious injury.

Install ball end of downrod into mounting 

bracket opening. Align (engage) slot on 

ball with tab on mounting bracket.

Warning:

 Failure to align slot on ball with 

tab may result in serious injury.

Important

: If using the angle mount, 

make sure open end of mounting bracket 

is installed facing the higher point of the 

ceiling and make sure the ceiling angle is 

not steeper than 20º. Longer downrod 

may be necessary allowing the fan blades 

to rotate without obstructions.    

Safety cable must be installed into the 

house structure using 3” lag screws, 

washers, and lock washers provided, 

required for outdoor applications and in 

Canada (All fans installed in Canada), and 

for USA fan and light kit combinations 

over 35lbs. 

Make sure that when the safety cable is 

fully extended the lead wires are longer 

than the cable and no stress is placed on 

the lead wires.

Note

: If Installing The Secondary Support 

Safety Cable in the U.S., Do Not Remove 
Knockouts In The Outlet Box.

  

SAFETY CABLE INSTALLATION

Lag screw

Safety cable

Washer

Lock washer

Cross pin

Keeper pin

Tab

Slot

After making the wire connections, the wires 

should be spread apart with the grounded 

conductor and the equipment-grounding 

conductor on one side of the outlet box and 

ungrounded conductor on the other side of 

the outlet box. The splices after being made 

should be turned upward and pushed carefully 

up into the outlet box.              

Lift Canopy allowing the 2 studs to 

protrude through the canopy and install 

the knurled nuts as shown. Tighten the 

knurled nuts securely. The canopy should 

adjust for any irregularity in the ceiling or 

Outlet box.

Make sure the studs protruding from the 

bottom of the Mounting bracket are 

installed with threads all the way through 

the bracket.    

To Wall 

Outlet Box

Black (Live)

Blue

White (Neutral)

Ground/Green

Ground/Green

White

Black

Blue

Grounded

wires

Ungrounded

wires

Stud

Refer to page 7

 

for wiring,

installation and operation of 

Wall controller. Do not operate 

the fan or light until it is 

installed completely.   

Summary of Contents for 3ERAR52 D Series

Page 1: ...NAME RETAILER ADDRESS Attach sales receipt to this card and retain as your proof of purchase To register your fixture please visit our website www montecarlofans com 3ERAR52XXXD Series Fan CUL Model N...

Page 2: ...nockouts in the outlet box Mount the secondary support safety cable through the reserved nail screw hole on the outlet box to the building structure or the ceiling joist WARNING To reduce the risk of...

Page 3: ...acket onto the outlet box Partially loosen the two screws on the outlet box attach the mounting bracket onto the outlet box by sliding it over the two screws as shown in the illustration Have the moun...

Page 4: ...ans installed in Canada and for USA fan and light kit combinations over 35lbs Make sure that when the safety cable is fully extended the lead wires are longer than the cable and no stress is placed on...

Page 5: ...ve 1 preassembled screw from light pan Save screw for later use Connect white wire from fan to white wire from light fixture and then connect blue or black wire from fan to black or blue wire from lig...

Page 6: ...t clockwise until tight Setting the reverse switch on the left hand side will result in downward airflow and setting the switch on the right hand side will result in upward airflow Note Reverse switch...

Page 7: ...ad wires from fan Connect the black white wire marked AC IN L from wall controller to the HOT wire from house and then connect the black wire marked TO MOTOR L of wall controller to the fan lead wire...

Page 8: ...unting bracket or mounting plate are tightened securely to 4 Check that all blade holders are tightened securely to motor 5 Most fan wobble problems are caused when blade levels are unequal Check this...

Page 9: ...Mar 2022...

Reviews: