2 Technical Data
2 Technical Data
2.1 X-3000ce-UW Electrical
AC Input
115 or 230 VAC +10% (IEC TC77B WG3) 48 to 62 Hz
Fuse Size (fuse not installed by factory)
115 V-160 mA T (slow-blowing type) Ø5 x 20 mm
230 V-80 mA T (slow-blowing type) Ø5 x 20 mm
(Both types are supplied)
Overvoltage Category
II (IEC 664)
2 kV in 1 minimum primary to secondary
Pollution Degree
2
Material Fire Classification
94V0
Maximum Power Consumption
12 VA
Maximum Fuse Input
10A
Noise Immunity
EN 50082-2 industrial
Noise Emission
EN 50081-1
Load Cell Supply
±2.5 VDC ±5%
Load Cell Input
0 to ±250m VDC
Zero Range (tare)
100% of load cell rating [max. 500mVDC (+/- 250 mVDC)]
Calibration Range
Gain: 11 to 480
Temperature Range
0 to 50° C (32 to 122° F) operating
-10 to 80° C (14 to 176° F) storage
Degree of Protection
IP 54 / IP 10 for non-cabinet version
Regulator Outputs
0 to 10 VDC
Maximum load - 5 mA
4 - 20 mA / 0-20 mA
R
L
= 0 to 1000
Ω
Meter Outputs
0 to 100 µA
R
O
= 100 K
Ω
0 to 10 VDC
Maximum load - 5 mA
Analog Input Voltage
0 to 10 VDC
R
I
= 100K
Ω
Digital Input Voltage
15 to 30 VDC
R
I
= 10K
Ω
Digital Output Voltage
24 VDC ±5%±15
Imax for a digital output: 100mA
Total Imax for all 4 outputs: 250mA (if internal power supply is used).
Standards
Designed to meet UL 508 and EN 60204