4.2 Regulation Parameter, Gain, Ratio, P and D
1/3/02 65
7.
Adjust potentiometer R2 until analog meter reading is identical to the hanging
weight.
(If non-cabinet version is used, see digital display: tension will appear as
a percentage value [%]).
8.
Remove weight and check that tension meter returns to zero. If not, repeat steps
4 to 7.
9.
If a second calibration range is used, repeat steps 4 to 8, using potentiometer R3
for calibration of second range.
4.2 Regulation Parameter, Gain, Ratio, P and D
Gain.
At small roll diameters, adjusts speed of regulator's response to errors. The
parameter can be adjusted in a range of 0 to 63 steps. The higher the value, the faster
the reaction to errors.
Not recommended:
parameters lower than 5.
Note:
To access setup menu, scroll to
[Password]
and enter 5.
Ratio.
At large roll diameters, the ratio adjusts speed of regulator's response to
errors. The parameter can be adjusted in the range of 0 to 63 steps. The higher the
value, the faster the reaction to errors.
Not recommended:
parameters lower than
10.
P-level.
Proportional gain level of the PID regulator. The parameter can be adjusted
in a range of 0 to 63 steps. The higher the value, the bigger the P- level in the PID
regulator.
D-level.
Derivative gain level of the PID regulator. The parameter can be adjusted in
a range of 0 to 63 steps. The higher the value, the bigger the D -level in the PID
regulator.
Note:
for load cell controllers, D-level is normally set at 0.
R1
R2
R3
R4
R5
R6
+
Back Space
Up
DO 4
DO 3
DO 2
DO 1
0
0
Load cell
KG
IL006.dsf
Diagnostic
Password
Setup Menu
Mode Menu
Run Mode
Amplifier
0/4mA
Language
Gain
Ratio
P Level
D Level
Softs Menu
Start Out
Softs Lev.
Softs Time
Hold Level
Anti Menu
Anti.Src.
Anti Max
Anti Min
Anti Slope
Splce Menu
Splice Src
Splice Del
Splice Lev
Splice Tim
WebBr Menu
Webbr Lev.
Webbr Time
Range Exp.
RE Source
Ranges
Start No.
Dn Level
Up Level
Range Time
Brake Menu
Range Dia Menu
Dia. Menu
Diamet.Src
P/Rev Roll
mm/Pulse
Min Diam.
Max Diam.
Fac. Diam
DF AutoSet
New Roll D
Diameter
Output2 Menu
Out2 Src
Out2 Slope
Out2 Scale