ADJUST HEIGHT AND LEVEL THE  

ICE MAKER

Height adjustments may be necessary to install  

the ice maker below a countertop, and may be 

accomplished by adjusting both the front and rear 

leveling legs. The ice maker must be level to operate 

properly.

To level and adjust the height:
1.  With one person holding the ice maker, carefully  

    tilt the machine to access the leveling legs.
2.  Use an adjustable wrench to turn the legs.

    – Turn legs right to lower, turn left to raise the ice 

maker.

3.  Check top and side with a level. Continue adjusting 

    legs until the ice maker is level and stable.

Raise

Lower

7

WATER SUPPLY SET-UP

•  A cold water supply 

with water pressure 

between 30 and 

120 p.s.i. is required 

for ice maker 

operation.

•  

7RDOORZVXȻFLHQW
ZDWHUÀRZWR

the ice maker, a 

minimum 1/2” 

diameter home 

supply line is recommended.

•  Route GE SmartConnect

 Kit or 1/4” O.D. copper 

tubing between house cold water line and the 

water connection location.

•  The water line should be long enough to extend to 

the back of the ice maker when the unit is moved 

forward for service.

•  Install tubing only in areas where temperatures 

will remain above freezing.

•  The water line should be flushed to clear any 

foreign material before connecting to the ice maker.

NOTE: The only GE approved plastic tubing is supplied 

in the GE SmartConnect

 Refrigerator Tubing kits. 

Do not use any other plastic water supply line. The 

line is under pressure at all times. Other types of 

plastic may crack or rupture with age and cause 

water damage to your home. Order parts below at 

GEApplianceParts. com or by calling 1.800.626.2002. 

GE SmartConnect

 Refrigerator Tubing Kits are 

available in the following lengths:
2’ (0.6 m) WX08X10002 

15’ (4.6 m) WX08X10015 

6’ (1.8 m) WX08X10006 

25’ (7.6 m) WX08X10025

Tools and Parts Needed:

Gather the required tools and parts before starting 

installation:

z

   Flat-blade screwdriver

z

   7/16” and 1/2” open-end wrenches or two 

adjustable wrenches

z

   1/4” nut driver

z

   1/4” (6.35 mm) soft copper or GE SmartConnect

™ 

tubing

NOTE: Do not use a piercing-type or 3/16” (4.76 mm) 

VDGGOHYDOYHZKLFKUHGXFHVZDWHUÀRZDQGFORJV

more easily.

Summary of Contents for ZDIC150

Page 1: ...Installation Instructions Automatic Ice maker ZDIC150 ZDIS15 Design Guide With Installation Instructions monogram com...

Page 2: ...installation is not covered under the GE Appliance Warranty See the Owner s Manual for warranty information Use this appliance only for its intended purpose Check with local utilities for electrical c...

Page 3: ...choice may be installed onto the 3 4 panel See installation instructions on pages 10 and 11 ZPK2 Drain Pump Kit For use when a floor drain is not available The drain pump must be installed inside the...

Page 4: ...d ZDIC150 models Install a 1 2 wide filler strip on the hinge side The filler strip will act as a spacer between the door case and adjacent cabinets and will prevent interference with the cabinet door...

Page 5: ...required Use an outlet which cannot be turned off by a switch or pull chain 5 ADVANCE PLANNING cont IMPORTANT This unit must NOT be on a GFCI Ground Fault Circuit Interrupter equipped outlet or nuisa...

Page 6: ...e ces instructions peut causer la mort un incendie ou un choc lectrique Do not use an extension cord or adapter plug with this appliance Follow National Electrical Code or prevailing local codes and o...

Page 7: ...The water line should be long enough to extend to the back of the ice maker when the unit is moved forward for service Install tubing only in areas where temperatures will remain above freezing The wa...

Page 8: ...molded end of the tubing into the ice maker connection Tighten the compression nut until it is just hand tight Tighten one additional turn with a wrench Over tightening can cause leaks Make sure there...

Page 9: ...proximately3 1 2 high 22 from the front or 22 3 4 when installing a 3 4 door panel Drain lines must be at least 5 8 inside diameter NOTE A drain pump is necessary when a floor drain is not available O...

Page 10: ...END CAP REVERSAL 1 Remove the hinge pin from the top hinge 2 Remove the door from the hinges and replace the top hinge pin 3 Remove the screw and door stop at upper left corner Remove the screw and e...

Page 11: ...r cabinet Turn hinge upside down so the hinge pin points down Place hinge on top opposite side of ice maker cabinet and tighten screws 5 Remove the top hinge pin REVERSE THE DOOR SWING cont REVERSE TH...

Page 12: ...fore installing pump Failure to do so can result in death fire or electrical shock Replace all panels before operating AVERTISSEMENT D branchez l alimentation lectrique la machine gla ons avant d inst...

Page 13: ...nstalled please proceed to Drain Pump Install section 1 Attach vent tube to pump with new 5 8 hose clamp Attach drain tube from bin to pump with 7 8 hose clamp 2 Coil ice machine power cord into a 4 d...

Page 14: ...orn NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice 7 8 Adjustable Hose Clamp Water Supply...

Page 15: ...ner as typical cabinet doors Order the custom panel from the cabinet manufacturer Be sure to provide the exact dimensions so that the panel is constructed accurately BEFORE YOU BEGIN Read these instru...

Page 16: ...the custom panel appearance side down on a clean surface 2 Align top and bottom side trim to the custom panel sides 3 Tape the side trim pieces to the back of the custom panel 4 Place the panel with...

Page 17: ...Notes 17...

Page 18: ...ety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance a...

Reviews: