Page 2: ...llation 9 Heater Installation 10 Flue Pipe Clearances 11 SECTION E Gas Connection 16 SECTION F Operating Instructions 17 Starting lnstructions 18 Adjusting Room Temperature 18 Turning Off the Heater 1...

Page 3: ...S APPLICANCE INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBEROR GAS FITTER WHEN INSTALLED WIT...

Page 4: ...ture Do not place yourself or others too close to the heater Installation of heater in extreme humidity or dust areas is not recommended Any removal of unit parts or remodeling is strictly forbidden D...

Page 5: ...nsert articles in the louvers Keep flammable materials trees shrubs etc away from flue pipe I Do not vent unit into other rooms Flue pipe must be outside k Do not install nor exhaust the flue pipe int...

Page 6: ...ed In open areas with strong wind a wind break may be necessary to avoid exhaust gases being blown back into the intake and causing poor combustion Must be higher Long Extension kit 1 eS J 1 60cm i fr...

Page 7: ...30minutes DUAL BLOWERS Separate fans for combustion and room air circulation THERMOSTATICALLY CONTROLLED Adjusts to the desired room temperature BUILT IN TIMER Heater will automatically operate as pro...

Page 8: ...ANDARD TOOLS APPLICATION Phillips Head Screwdriver Installation of HeaterParts Steel Tape Measure TakingMeasurements Pen or Pencil Marking Drilling Location Exterior Caulk Caulking Between Packing and...

Page 9: ...d accessory kits available from your Monitor or dealer ACCESSORY APPLICATION Medium Adjustable Flue Pipe Kit P N 8051 Long Adjustable Flue Pipe Kit P N 8052 For use where wall thickness is up to 121 A...

Page 10: ...MUST NOT BE EXCEEDED 1 Trie total length of the intake or exhaust pipe should not exceed 10 feet 3 05m with 3 elbows 13 feet 3 96m with 2 elbows or 16 2 feet 5 3m with 1 elbow 2 These elbows should in...

Page 11: ...e done by a licensed or qualified service person Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a qualified...

Page 12: ...rds must not be used The area outside where the flue pipe will emerge should be free of foliage fuel storage tanks and flammable objects Air should circulate freely in the area Allow the clearances sh...

Page 13: ...lls or obstacles must comply with the requirements shown below Frontal Clearance ts l l CAUTION Do not attach anything onto the outlet of the flue pipe Combustible i minimim f 24 61cm or more 13 5cm B...

Page 14: ...e the insulation Make sure there are no obstructions inside the wall such as electrical wiring water pipes hot air ducts etc 6 35cm V J Outdoof 0 64cm Fig 7 Room Flue Pipe A 1 4 0 64c Fig 9 Step 6 The...

Page 15: ...g 12 Flue Pipe B Wall Thickness 3 s 5 inches 1 Set the Sleeve nut onto Flue Pipe B by turning the Sleeve Nut counter clockwise Slide the Outer Flange and the Rubber Packing onto Flue Pipe B Figure 13...

Page 16: ...Fig 17 Step 9 Install the Joint Pipe At the rear of the heater slide the large end opening of the joint pipe into the exhaust port outlet of the heater Be sure the joint pipe is fully seated Slide the...

Page 17: ...oceeding check again to be sure there are no flammable materials close to the heater Re check that the heater is level Examine the flue pipe to be sure connections are tight Flue Pipe Holder Fig 19 WA...

Page 18: ...excess of 1 2 psi 3 5kPa The appliance must be isolated from the gas piping system by closing its equipment shutoff valve during any pressure testing of the gas supply piping system at test pressure e...

Page 19: ...inspect the appliance and to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS STOP Read the safety information above on this label 1 Set the...

Page 20: ...desired room temperature is reached While it cycles you may hear the circulation fan change speed Depending on the output required to maintain thedesired room temperature The heater will shut itself...

Page 21: ...luminate and flash the Light of the current day of the week e g Wed by pressing the UP or DOWN Button and then press the SET Button to lock into memory The current day e g Wed light will illuminate co...

Page 22: ...iday You can easily duplicate Monday s program for the remainder of the week or any group of days by using the Copy function After having set the program for Monday press the 1st 4th Button until COPY...

Page 23: ...while the CHILD LOCK is activated it cannot be turned ON again until the lock is deactivated OVERHEAT PREVENTION If your heater overheats a thermostatic switch will automatically stop the flow of gas...

Page 24: ...cover and grill assemblies See Step 5 Page 21 and vacuum and wipe away dust and other accumulation Cleaning the Blower Guard Heating efficiency will be reduced if the blower guard at rear of the cabi...

Page 25: ...y programmed Power interruption Depress operation button to ON position Press Auto Button See Programming for Automatic Operation page 20 See Loss of Power page 21 Poor flame sounds of combustion soot...

Page 26: ...replaced it must be replaced with a wire of at least a 105 C temperature rating CODE Bk Bl Br G Or R W Y Gr COLOR Black Blue Brown Gray Orange Red White Yellow Green MARK BM ER F FM FR FT OHT PS RC1 4...

Page 27: ...1 1 1 1 1 1 1 1 1 1 1 1 1 1 REMARK NO 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 PARTS NAME BURNER ASSY MIXING PLATE ASSY BURNER PORT A...

Page 28: ...GUIDE OUCH UP PAINT WHITE OUCH UP PAINT M2400 GREY abinet Screw Assortment LUNGER ASSY RIFICEfNAT HA PARTS NO 6905 6914 6704 6652 6718 6194 4004 4006 6145 8050 6723 6148 4014 4016 4805 4008 6653 6654...