ARDAC WACS-2 Specification and Adjustment Manual
44X477 Rev. 8
05/ 16/ 03 4-12
To Show Calibration Voltages:
After communications are established and the acceptor has been enabled, press the V key. A display similar
to the one below will appear on the computer display.
Ardac OS>>> V
Top Vis Voltage = 1.99 Volts (102) ee pot: 21/31
Top IR Voltage = 1.95 Volts (100) ee pot: 19/31
Bottom Vis Voltage = 2.08 Volts (107) ee pot: 19/31
Bottom IR Voltage = 2.07 Volts (106) ee pot: 22/31
Left Front Voltage = 4.70 Volts (target=4.72 V) DAC Setup = 100/255
Right Front Voltage = 4.72 Volts (target=4.72 V) DAC Setup = 113/255
IR Density Voltage = 4.76 Volts (target=4.72 V) DAC Setup = 224/255
Red Density Voltage = 4.72 Volts (target=4.72 V) DAC Setup = 119/255
String Detect Voltage = 2.34 Volts (target=2.34 V) DAC Setup = 128/255
IR Density Calibration: Slope=050, Diffusion 0.17, Cal Open V=4.88
Red Density Calibration: Slope=097, Diffusion Offset=-0.31, Cal Open V=4.72
****** CALIBRATION PASSED ******
PRESS <ENTER> TO CONTINUE...
Current Mag Gain Value = 23
DIP Switch1: 1 2 3 4 5 6 7 8
off off off off off off off off
Note present front :UNcovered
Rear clear :UNcovered
Note present back :UNcovered
Stacker Home
Stacker Installed
Table 4-4
Diagnostic (Bench) Mode Voltage Printout