SR3 Type 1 Technical Manual
TSP005.doc Issue 5.0 – Jan 2005
Money Controls 2005. All rights reserved.
Page 32 of 50
19.2 Set Bonus Level 1
Example:-
When the game price is £1 and a bonus level is required at £2.50.
Switch off the power to the SR3.
Set the Program DIL switches to:-
SW1
SW2
SW3
SW4
SW5
SW6
OFF
ON
ON
OFF
OFF
OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will turn RED.
Insert any combination of programmed coins that total £2.50 and check that they are
accepted, i.e. 2 x £1 + 1 x 50p, 5 x 50p etc.
Press the reject lever to return to normal operational mode.
The LED will turn GREEN.
Return ALL the DIL switches to the OFF position.
19.3 Set Bonus Level 2
Example:-
When the game price is £1 and bonus level 2 is required at £5.00.
Switch off the power to the SR3.
Set the Program DIL switches to:-
SW1
SW2
SW3
SW4
SW5
SW6
OFF
ON
ON
ON
OFF
OFF
Switch on the power to the SR3.
Press the reject lever within 20 seconds.
The LED will turn RED.
Insert any combination of programmed coins that total £5.00 and check that they are
accepted, i.e. 5 x £1, 10 x 50p etc.
Press the reject lever to return to normal operational mode.
The LED will turn GREEN.
Return ALL the DIL switches to the OFF position.